34
M0604-1 ver. 2.3
4.4.3 Replacement of O-ring
Action
Note
1
Remove the O-ring on the ball
holder at the tool changer.
2
Clean the surface at the O-ring
location.
3
Add a small amount of grease
(Magnalube-G) on the new O-
ring.
4
Mount the new O-ring.
4.5 Complete service of tool changer
We recommend a complete service on tool changers to be carried out every 5 years. This will
ensure proper function and increase the lifespan of the tool changer considerably. We further
recommend that the maintenance shall be carried out by qualified RSP personnel. Please
contact us for a quotation.
The 5 year tool changer service at Robot System Products includes inspection and cleaning of
the full unit, replacement of all wear parts including sealings and signal pins.
4.6 Replacement of tool changer
Recommended tools
Tools
Applications
Complete set of Allen keys
For dismounting and mounting of tool changer
Torque wrench
For all socket head cap screws
Содержание P0602