5.5 Mounting of tool present sensor
Action
Note
1
Safety
Read the safety section (1.1).
2
Fit tool present sensor
Fit the tool present sensor to
the tool hanger and fasten
the two enclosed M4x25
screws lightly.
3
Adjust tool present sensor
Adjust the tool present
sensor. It shall protrude
between 16 and 18 mm from
the sensor holder.
NOTE!
IF present sensor
protrudes more than 18 mm
from the sensor holder It
might be damaged during
docking.
4
Fasten present sensor
Fasten the tool present
sensor with the M4x25
screws.
5
Connect present sensor
Connect the tool present
sensor according to circuit
diagram E0186-040 (section
2.6.10).