background image

2011/11/10 Ed 1.5   

 

Setup and Programming manual for XT series GPRS 

 

41 | 

P a g e

 

4455 White Bear Parkway, Suite 700 

White Bear Lake, MN 55110 

AREAS AND DEVICES 

 

AREAS AND 

DEVICES

EXIT DELAY

45sec

ENTRY DELAY

15sec

SIREN DURATION 

TAMPER 90sec

SIREN DURATION 

INTRUSION 90sec

CHANGING NAME 

AREA

LIST OF DEVICES 

IN AREA

AREA CONTENT

LIST OF AREAS

AREAS

24H SIREN MODE

24 HOUR DEVICE 

DISABLED

CHANGING AREA 

DEVICE

CHANGING NAME 

DEVICE

DELETE DEVICE

LIST OF DEVICES

DEVICE 

CONFIGURATION

ADD A NEW 

DEVICE

DEVICES

DELAY BEEPS 

ENABLED

AUTO ARMING 

DELAY DISABLED

SCEDULING

SCHEDULING OFF

CALENDAR 

MANAGEMENT

WARNING BIP 

DISABLED

 

 
 
 

 

 
 
 
 
 

Содержание XT600i

Страница 1: ...y White Bear Lake MN 55110 877 206 5800 COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT610 XTX610 XTO610 GPRS PANELS A Videofied CMA601 XMB611 June 2011 Alphanumeric Keypad or Frontel TMT2 is required for programming and maintenance CMA601 XMB611 ...

Страница 2: ... Testing GPRS Level 19 Testing Device RF Level 20 Connecting a GPRS Antenna 21 Arming Input Wiring Diagram 21 Programmable Input Configuration 22 24 Programmable Output Configuration 25 27 Configuring Scheduling 28 30 Enabling External RF Antenna 31 Mounting XT XTX 32 Mounting XTO 32 33 Troubleshooting 34 36 Central Station not getting Video 34 Central Station not getting any signals 35 Panel sayi...

Страница 3: ...r television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the...

Страница 4: ...our keypad to run the RF test for each device If you get a 9 9 for your RF test on the first device then mount it If not you will need to move the device to get optimal signal Page 18 Note If you are not getting an appropriate GPRS or RF level you can add an external antenna for either signal Not available for the XL600 Note Re enable monitoring before you send signals Page 14 8 5 If you are curre...

Страница 5: ...oviding optimum signal integrity and security The bi directional RF communication path between all devices and the system control panel guarantees high signal reliability Integrated antennas eliminate protruding wires or rods which are difficult to install unsightly to consumers and potentially troublesome if damaged The panel supervises every device excluding the remote key fob to validate curren...

Страница 6: ... CMA601 XMB611 or TMT INSTALLER SOFTWARE FOR PROGRAMMING XT Initial Programming The cover will fold off the panel like a book with the curved side acting like the binding The same technique is used when placing the cover back onto the unit Open the Control Panel Using a 1 Phillips screwdriver remove the 2 screws holding the cover on When removing the XTO cover pull straight off do not slide it ...

Страница 7: ...perating Temp 76 F to 230 F Storage Temp Dry Ventilated 86 F Max 4 x E95VP Alkaline D Cell 12v 2amp DC Class 2 power supply not supplied Used for Standalone or Xtender mode where Programmable Inputs Mapping Programmable Outputs or SMS will be used E95VP Specifications Operating Temp 0 F to 130 F E95VP Technical Specifciations Nominal Capacity 8900 mA hours Nominal Voltage 1 5 V LSH20 Technical Spe...

Страница 8: ...kway Suite 700 White Bear Lake MN 55110 Obtaining XMB Keypad Special Characters Obtaining CMA Keypad Special Characters WARNINGS 1 DO NOT USE ALKALINE BATTERIES IF INSTALLING AN XTX XTO GPRS BELOW 30 F YOU MUST USE OPTION 1 PP1 2 DO NOT INSTALL A TRANSFORMER WHEN USING OPTION 1 LITHIUM BATTERIES ...

Страница 9: ...s now in Learn Mode for the CMA601 keypad CLR ESC NO XX Insert all three batteries into the CMA601 and press both the ESC NO and CLR keys at the same time and release The indicator LED on the keypad will blink rapidly YES KEYPAD 1 RECORDED RSI c 2005 www RsiAlarm com LANGUAGE ENGLISH or for language selection YES to apply Other languages are available by scrolling with arrows ITALIANO NEDERLANDS D...

Страница 10: ...he installer code using the Alphanumeric Keypad If you leave the name blank it will default to ACCESS 1 Use the or to set the Year Use the or to set the Month RADIO RANGE TEST YES The Radio Range test should be run during device recording to ensure proper pairing with the control panel This test is the communication strength between the device and the control panel The keypad will display a real t...

Страница 11: ...arrows for the selection and press YES to confirm We suggest at least a 24 hour test or for period selection and YES to apply DATE Day 09 06 01 DATE Day 09 06 03 YES YES YES Use the or to set the Day Use the or to set the Hour The system uses a 24 hour clock Use the or to set the Minutes YES Use the Alphanumeric Keypad to enter in a 4 8 digit account number provided by the Central Station TIME HOU...

Страница 12: ...t Transmitted Tamper Alarm End Device Batt Alarm End Radio Jamming Not Transmitted Supervision Alarm End Periodic Test Alarm Wrong Codes Not Transmitted Duress Code Alarm Alarm Memory Not Transmitted Arm Disarm Not Transmitted If you would like to change the state press YES and use the or to toggle between Alarm Appearance Alarm End Appearance and Restoral Not Transmitted Not Transmitted If you wo...

Страница 13: ... keypad up to 600 seconds the transmission of any event will be delayed that many seconds Enter the value you would like for the Transmission Delay and press YES Arming Confirmation is the number of seconds of latched voltage where voltage must stayed latched after the panel will require before arming This will be considered your exit delay Enter the value you would like for the Arming Confirmatio...

Страница 14: ...y and the arrow to move to the next parameter Your IP1 address is given to you by your Central Station Press YES to enter into the parameter and use the Keypad to complete the address Press YES to confirm your entry and the arrow to move to the next parameter You will use either a IP address or a Domain Name but not both When entering an IP address you must enter all 12 digits including preceeding...

Страница 15: ...ESC NO and CLR keys This test can take up to 5 minutes Once the level or error has posted press YES to continue in programming For explanation of GPRS errors see bottom of page Videofied will require a 3 5 or better for reliable transmission of Video alarms Each device has a unique programming button Please reference the Installation Sheet for the device you would like to program Before completing...

Страница 16: ...served for Silent Duress and Audible Duress The XT system can accept up to 19 Badges or Access codes in any combination If you are entering any additional codes press YES If you have completed entering Badges and Codes press and hold ESC NO for 5 seconds to return to the main manu Use the keypad to name the badge or code or leave it blank for the default name ACCESS Confirm the code by re entering...

Страница 17: ...Only delay beeps are sounded by the interior siren The letter underneath the area describes which devices will be armed when this profile is used To change you must press the corresponding area number to cycle through the different letters A All Devices Armed D All Devices Disarmed E Only external devices armed P Only perimeter device armed Use the to move to ALARM MODES PROGRAMMABLE Use the arrow...

Страница 18: ...ed Press YES to continue After pressing YES the keypad will tell you which device has been triggered Press YES to continue Once the delay has expired and the keypad says SYSTEM ARMED put motion in front of a MotionViewer If the MotionViewer is in area 1 you will need to wait for the entry delay to expire before disarming the system Once the system has gone into alarm enter a User Code followed by ...

Страница 19: ... you will have access to programming throughout your troubleshooting Press YES on MONITORING ENABLED and use the to change the value to DISABLED and press YES to lock it in Press and hold ESC NO for 5 seconds to return to the main menu Use the to move to CONFIGURATION MONITOR STATION Press YES on MONITORING PARAMETERS Press the to move to CONFIGURATION Enter the installer code for the system Enter...

Страница 20: ... 256 Cannot connect to cell tower 11 SIM not ready if multiples SIM not detect if only one 48 Signal rejected by host IP Domain Name or Port are incorrect 10 12 27 10 53 DISARMED LVL 3 GPRS LEVEL TEST IN PROG YES END Press the arrow to move to MAINTENANCE Press the arrow to move to GPRS LEVEL GPRS LEVEL Press and hold ESC NO for 5 seconds to return to the main menu This test can take up to 5 minut...

Страница 21: ... DEVICE NAME Press and hold ESC NO for 5 seconds to return to the main menu This test will run as long as you need it to Pressing the YES ESC NO or CLR buttons will end the test This test will show the results on the display of the keypad relative to the number of successful pings to the panel It is required to run the test for at least 30 seconds at the mounting location for accurate results and ...

Страница 22: ...emoving antenna connection Damaged antenna connector is NOT covered under warranty Using needle nose pliers be sure to only grab the connector and pull directly up Arming Input Wiring Diagram _ HOST When in Arm From Host mode the Videofied system will only arm and disarm when 9 12v is supplied and sustained Arming Input 1 will arm disarm Areas 1 2 Arming Input 2 will arm disarm Areas 3 4 ...

Страница 23: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 23 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 General Programmable Input Configuration ...

Страница 24: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 24 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 25: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 25 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 26: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 26 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 27: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 27 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 28: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 28 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 29: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 29 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 30: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 30 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 31: ...2011 11 10 Ed 1 5 Setup and Programming manual for XT series GPRS 31 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 ...

Страница 32: ... initial programming The following steps will walk you through how to enable the High Gain RF antenna after initial programming Left or Right arrow until you see RADIO OPTIONS and press YES Use the arrow keys to change it to External and press YES Enter the Installer Code Press the arrow to move to CONFIGURATION Enter the Installer code Press the arrow to move to ACCESS LEVEL Press YES and use the...

Страница 33: ...hite Bear Lake MN 55110 How to mount the XT600i 610 and XTX600 610 How to Mount the XTO600 610 Included Mounting Hardware 1 Install the Weather Resistant Wire Port How to Mount the Control Panel Fix the back casing on the wall with 3 screws Mounting Brackets Case and Mounting Screws locking washers bolts and nuts ...

Страница 34: ... base 3 Screw the cover to the base using the provided 8 screws 4 Place the L shaped mounting bracket onto the base using the provided bolts 5 Place the two U shaped brackets around the pole and attach the locking bracket Use the locking washers and nuts to attach the U bracket to the L mount 1 When closing the cover be sure to line up the two BOTTOM stickers face to face 2 Be Careful not to slide...

Страница 35: ...y Devices YES There are faulty devices NO There are no faulty devices Run Maintenance Device Locating MotionViewers come up with Radio Problem This means that the MotionViewers are currently not talking with the Control Panel Bring the devices back to the Control Panel and hit the programming button to force them to sync back with the panel Device Locating will test the RF signal strength between ...

Страница 36: ...smission See Page 16 for Event Log GPRS meanings GPRS LEVEL RECEIVED Your signal strength must be 3 5 or better for reliable transmission to the monitoring station There are external antennas available and other cellular repeater options if needed to boost cellular reception GPRS Level 0 5 2 5 GPRS Level 3 5 5 5 Panel is staying CONNECTED WITH MONITOR STATION While the Control Panel is attempting ...

Страница 37: ...anel s programming button DO NOT HOLD THE PANEL S PROGRAMMING BUTTON o B If learning in additional devices make sure the keypad reads Press Programming Button Of Device o 3 Insert a single battery into the device o 4 Wait 1 second for device to power up o 5 Press programming button of device for keypads press CLR ESC NO keys at the same time For the 4 button remote keyfobs the process is slightly ...

Страница 38: ...LY ARMED ALARM MODES PROGRAMMABLE EXIT DELAY 45sec ENTRY DELAY 15sec SIREN DURATION TAMPER 90sec SIREN DURATION INTRUSION 90sec AREAS DEVICES AREAS AND DEVICES EMAIL SENDER VIDEOMAIL ALARM ADDRESS RESPONDING PARTY LIST DELAY BEEPS ENABLED AUTO ARMING DELAY DISABLED WARNING BIP ENABLED SCHEDULING ALARM CODES PERIODIC TEST MONITORING PARAMETERS CONFIGURATION MONITOR STATION Not Supported in the Nort...

Страница 39: ... MODE ALARM INPUT TYPE NORMALLY OPEN EVENT TYPE INTRUSION INPUT NAME SIREN MODE MAPPING DISABLED PROGRAMMABLE INPUT 2 PROGRAMMABLE INPUT 3 GPRS PARAMETERS APN CODE USERNAME PASSWORD IP ADDRESS 1 0 0 0 0 DOMAIN NAME 1 PORT 1 888 IP ADDRESS 2 0 0 0 0 DOMAIN NAME 2 PORT 2 888 TMT IP ADDRESS 0 0 0 0 DOMAIN TMT PORT TMT 888 PAQUET SIZE 512 DATA TIMEOUT 20 SMTP GPRS PORT GPRS 3389 MAX TCP PACKET RINGTON...

Страница 40: ...NG PARTY LIST ALARM MODES PROGRAMMABLE DESIGNATION MODE ALARM SIREN AREAS 1234 STATE AAAA ALARM MODE SP2 DESIGNATION MODE ALARM SIREN AREAS 1234 STATE AAAA ALARM MODE SP1 ALARM SIREN AREAS 1234 STATE AAAA FULLY ARMED EMAIL SENDER ENTER NEW EMAIL ADDRESS SELECT MODIFY EMAIL ADDRESS VIDEOMAIL ALARM ADDRESS RESPONDING PARTY LIST Not supported in the North American Market ...

Страница 41: ...c SIREN DURATION TAMPER 90sec SIREN DURATION INTRUSION 90sec CHANGING NAME AREA LIST OF DEVICES IN AREA AREA CONTENT LIST OF AREAS AREAS 24H SIREN MODE 24 HOUR DEVICE DISABLED CHANGING AREA DEVICE CHANGING NAME DEVICE DELETE DEVICE LIST OF DEVICES DEVICE CONFIGURATION ADD A NEW DEVICE DEVICES DELAY BEEPS ENABLED AUTO ARMING DELAY DISABLED SCEDULING SCHEDULING OFF CALENDAR MANAGEMENT WARNING BIP DI...

Страница 42: ... Lake MN 55110 CONFIGURATION MONITOR STATION CONFIGURATION MONITOR STATION TRANS STATE MODIFICATION ALARM CODES SYSTEM ARMED DISABLED TEST HOUR 15 00 PERIODIC TEST 24 HOURS PERIODIC TEST ACCOUNT NUMBER MONITORING ENABLED MONITORING PARAMETERS LIST OF TRANSMITTED EVENTS PPP CONNECTION PPP USER NAME PPP PASSWORD DOMAIN NAME ...

Страница 43: ...Programming manual for XT series GPRS 43 P a g e 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 Addendum 1 LSH20 Control Panel Batteries 2 LS14500 Peripheral Batteries Excludes SE601 and SE651 3 Lithium Battery Storage ...

Страница 44: ...ay Suite 700 White Bear Lake MN 55110 4 Finding Manufacture Week and Year The Manufacture week and year can be found in the serial number of the device control panel The second sets of 4 numbers in the serial number are WWYY 0411 Which shows that this device was manufactured in the 4th week of 2011 ...