2011/11/10 Ed 1.5
Setup and Programming manual for XT series GPRS
17 |
P a g e
4455 White Bear Parkway, Suite 700
White Bear Lake, MN 55110
Changing Siren Options
After initial programming has been completed any sounder on the system will be enabled by default,
this includes the sounder on the Keypad and Badge Reader. While there is no way to disable the
sounding of the exit delay you are able to disable the intrusion sound.
Use the arrow keys to find the siren type you would like for
the chosen profile.
SIREN : All sounders are triggered during intrusion
SILENT : No sounders are triggered during intrusion
WITHOUT SIREN : Only arming device sounders are
triggered during intrusion.
DELAY BEEPS : Only delay beeps are sounded by the
interior siren.
The letter underneath the area describes which devices will
be armed when this profile is used. To change you must
press the corresponding area number to cycle through the
different letters.
A= All Devices Armed
D= All Devices Disarmed
E= Only external devices armed
P= Only perimeter device armed.
Use the
to move to ALARM MODES PROGRAMMABLE
Use the arrow keys to find the arming profile you would like to
configure
Press the
to move to CONFIGURATION
Enter the installer code for the system
Enter the installer code for the system
Press the
arrow to move to ACCESS LVL.
Use your arrow keys to change the level to 4
YES
YES
ALARM:
WITHOUT SIREN
YES
BADGE OR CODE
GENERAL
PARAMETERS
SP2
SP1
YES
YES
BADGE OR CODE
****
YES
ALARM MODES
PROGRAMMABLE
ACCESS LVL: 4
FULLY ARMED
AREAS: 1234
STATE: AAAA
CONFIGURATION
ACCESS LEVEL
3
10/12/27 10:53
DISARMED LVL:3