45
Fla
g
Name
Description
I/O flag number
(NX-POSI1, NX-
POSI2)
I/O flag number
(NX-POSI3, NX-POSI4)
1st
axis
2nd
axis
1st
axis
2nd
axis
3rd
axis
4th
axis
Y_0
E point
control start
EST
When turned ON in the user
program, E point control is
initiated.
Y20
Y30
Y40
Y50
Y60
Y70
Y_1
P point
control start
PST
When turned ON in the user
program, P point control is
initiated.
Y21
Y31
Y41
Y51
Y61
Y71
Y_2
Home return
start
ORGS
When turned ON in the user
program, a home return is
initiated.
Y22
Y32
Y42
Y52
Y62
Y72
Y_3
Forward JOG
JGF
When turned ON in the user
program, JOG forward
rotation is initiated.
Y23
Y33
Y43
Y53
Y63
Y73
Y_4
Reverse JOG
JGR
When turned ON in the user
program, JOG reverse rotation
is initiated.
Y24
Y34
Y44
Y54
Y64
Y74
Y_5
Forced stop
EMR
When turned ON in the user
program, operations currently
running are interrupted and
forcibly terminated.
Y25
Y35
Y45
Y55
Y65
Y75
Y_6
Deceleration
stop
DCL
When turned ON in the user
program, operations currently
running are interrupted, and
decelerate to a stop.
Y26
Y36
Y46
Y56
Y66
Y76
Y_7
Pulser input
enabled
PEN
When turned ON in the user
program, pulser input is
enabled (valid only while on).
Y27
Y37
Y47
Y57
Y67
Y77
Y_8
Y28
Y38
Y48
Y58
Y68
Y78
Y_9
Y29
Y39
Y49
Y59
Y69
Y79
Y_A
Y2A
Y3A
Y4A
Y5A
Y5A
Y5A
Y_B
Y2B
Y3B
Y4B
Y5B
Y5B
Y5B
Y_C
Y2C
Y3C
Y4C
Y5C
Y5C
Y5C
Y_D
Y2D
Y3D
Y4D
Y5D
Y5D
Y5D
Y_E
Y2E
Y3E
Y4E
Y5E
Y5E
Y5E
Y_F
Error clear
ECLR
If a error occurs, the error is
canceled when this is turned
ON in the user program.
Y2F
Y3F
Y4F
Y5F
Y6F
Y7F
Содержание NX-POSI1
Страница 1: ...Catalog Number s NX70 POSIx NX POSIx NX70 700 Position User Manual ...
Страница 6: ...6 ...
Страница 14: ...14 ...
Страница 22: ...22 ...
Страница 38: ...38 ...
Страница 64: ...64 ...
Страница 79: ...79 Program ...
Страница 82: ...82 Program ...
Страница 106: ...106 Pulse output diagram ...
Страница 107: ...107 Sample Program ...
Страница 110: ...110 ...
Страница 123: ...123 Action of the I O Flag Before and After a Home Return Operation Return Operation ...
Страница 132: ...132 ...
Страница 145: ...145 11 Deceleration Stop and Forced Stop Sample Program In progress Stopping Emergency Stopping Overrun ...
Страница 147: ...147 Pulse output diagram Deceleration stop operation In progress stop ...
Страница 148: ...148 Forced stop operation Emergency stop Overrun ...
Страница 158: ...158 ...
Страница 170: ...170 ...
Страница 178: ...178 Oriental Motor Co Ltd UPK W Series Open collector output stepping drive connection ...
Страница 179: ...179 NX700 PLC External Dimensions 1 System Dimensions mm Motherboard Installation Diagram mm ...
Страница 180: ...180 2 CPU I O Analog Unit Dimensions mm 3 Special Unit Dimensions mm ...
Страница 183: ...183 Program ...
Страница 187: ...187 Program ...
Страница 188: ...188 ...
Страница 194: ...Publication NX700 UM007A PositionA EN December 2010 ...
Страница 195: ......
Страница 196: ...Copyright 2010 RS Automation Co Ltd All rights reserved ...