Contents of Input and Output Allocations
( *1): This goes ON during pulse output in various operations such as E point control, P point control,
home return, JOG operation, JOG positioning operation and remains ON until the operation
has been completed.
( *2): This goes ON when the various operations such as E point control, P point control, JOG
operation, JOG positioning operation, and pulser input operation have been completed. It also
goes ON when deceleration stop have been completed, and when a forced stop has been
completed. It goes OFF when the next operation such as E point control, P point control, JOG
operation, JOG positioning operation, a home return, or pulser input operation is initiated.
( *3): This goes ON when Home return is completed. It goes OFF when the next operation such as E
point control, P point control, JOG operation, JOG positioning operation, a home return, or
pulser input operation is initiated.
( *4): The input and output flag numbers indicate the number when the slot number is 0. The numbers
actually used change depending on the position in which the unit is installed.
Fla
g
Name
Description
I/O flag number
(NX-POSI1, NX-
POSI2)
I/O flag number
(NX-POSI3, NX-POSI4)
1st
axis
2nd
axis
1st
axis
2nd
axis
3rd
axis
4th
axis
X_0
Pulse output
busy
BUSY
ON during pulse output.
(* 1)
X0
X10
X0
X10
X20
X30
X_1
Pulse output
done
EDP
Goes ON when pulse output
ends. (* 2)
X1
X11
X1
X11
X21
X31
X_2
Acceleration
zone
ACC
ON during acceleration zone.
X2
X12
X2
X12
X22
X32
X_3
Constant
speed zone
CON
ON during constant speed
zone.
X3
X13
X3
X13
X23
X33
X_4
Deceleration
zone
DEC
ON during deceleration zone.
X4
X14
X4
X14
X24
X34
X_5
Rotation
direction
DIR
Monitors direction of rotation
(On during the elapsed value
increment)
X5
X15
X5
X15
X25
X35
X_6
Home input
ZSG
Goes ON when home input
becomes valid
X6
X16
X6
X16
X26
X36
X_7
Near home
input
DOG
Goes ON when near home
input becomes valid
X7
X17
X7
X17
X27
X37
X_8
Home return
done
ORGE
Turns ON when home return
is done.
X8
X18
X8
X18
X28
X38
X_9
Comparison
result
CLEP
ON when elapsed value of
internal counter is greater than
or equal to the number of
comparison pulse.
X9
X19
X9
X19
X29
X39
X_A
Set value
change
confirmation
CEN
With P point control, this is used
to confirm rewriting of set
values. (* 3)
XA
X1A
XA
X1A
X2A
X3A
X_B
XB
X1B
XB
X1B
X2B
X3B
X_C
XC
X1C
XC
X1C
X2C
X3C
X_D
XD
X1D
XD
X1D
X2D
X3D
X_E
Set value
error
SERR
ON when a set value error
occurs.
XE
X1E
XE
X1E
X2E
X3E
X_F
XF
X1F
XB
X1F
X2F
X3F
Содержание NX-POSI1
Страница 1: ...Catalog Number s NX70 POSIx NX POSIx NX70 700 Position User Manual ...
Страница 6: ...6 ...
Страница 14: ...14 ...
Страница 22: ...22 ...
Страница 38: ...38 ...
Страница 64: ...64 ...
Страница 79: ...79 Program ...
Страница 82: ...82 Program ...
Страница 106: ...106 Pulse output diagram ...
Страница 107: ...107 Sample Program ...
Страница 110: ...110 ...
Страница 123: ...123 Action of the I O Flag Before and After a Home Return Operation Return Operation ...
Страница 132: ...132 ...
Страница 145: ...145 11 Deceleration Stop and Forced Stop Sample Program In progress Stopping Emergency Stopping Overrun ...
Страница 147: ...147 Pulse output diagram Deceleration stop operation In progress stop ...
Страница 148: ...148 Forced stop operation Emergency stop Overrun ...
Страница 158: ...158 ...
Страница 170: ...170 ...
Страница 178: ...178 Oriental Motor Co Ltd UPK W Series Open collector output stepping drive connection ...
Страница 179: ...179 NX700 PLC External Dimensions 1 System Dimensions mm Motherboard Installation Diagram mm ...
Страница 180: ...180 2 CPU I O Analog Unit Dimensions mm 3 Special Unit Dimensions mm ...
Страница 183: ...183 Program ...
Страница 187: ...187 Program ...
Страница 188: ...188 ...
Страница 194: ...Publication NX700 UM007A PositionA EN December 2010 ...
Страница 195: ......
Страница 196: ...Copyright 2010 RS Automation Co Ltd All rights reserved ...