Hydraulic system connection
48
FA ROTEX Solaris RPS3 P2 - 06/2012
Table 7-1 Short names in hydraulic drawings
Series connection
As an alternative to the parallel circuits of the solar panels described in these instructions (see also image 2-1), if required a
maximum of three rows of solar panels can also be installed above one another. Solar panels or solar panel arrays installed in
this way must be connected in series (image 7-4). For the selected solar system, one pack of row connectors CON LCP
(
16 20 45) is required for each additional row of solar panels.
Fig. 7-4
Alternative solar panel arrangement
T
K
Solaris collector temperature sensor
Supplied with RPS3 P2.
T
R
Solaris return temperature sensor
T
S
Solaris storage tank temperature sensor
T
V
Solaris flow temperature sensor
Included with FLS20.
UV1
3-way switch valve
Supplied with AMK1.
VS
Scalding protection VTA 32
Accessories
15 60 15
Short name
Meaning
Remark
Order No.
1
Collector connector
2
Mounting rail
3
Collector securing hook
4
Solaris flat collector
5
Return flow connection collector
6
Inflow connection collector
7
Collector sealing cap
8
Customer-fitted ventilation slate for roof penetration pipes flow and
return flow
9
VA 18 Solar return flow pipe
10
VA 15 Solar inflow pipe
11
Panel row connector CON LCP
12
Solaris solar panel (2x 2 collectors)