Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[6-02]
R/W
0~10kW, step: 0,2kW
0kW
A.8
[6-03]
R/W
0~10kW, step: 0,2kW
3kW
A.8
[6-04]
R/W
0~10kW, step: 0,2kW
0kW (*3)
6kW (*4)
A.8
[6-05]
0
A.8
[6-06]
0
A.8
[6-07]
R/W
0~200W, step: 10W
0W
A.8
[6-08]
R/W
2~20°C, step: 1°C
10°C
A.8
[6-09]
0
A.8
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
A.8
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
A.8
[6-0E]
R/W
[E-07]
≠
1 : 40~80°C, step: 1°C
60°C
[E-07]=1 : 40~60°C, step: 1°C
60°C
A.8
[7-00]
R/W
0~4°C, step: 1°C
0°C
A.8
[7-01]
R/W
2~40°C, step: 1°C
2°C
A.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.8
[7-03]
2,5
A.8
[7-04]
0
A.8
[7-05]
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
A.8
[8-00]
1 min
A.8
[8-01]
R/W
5~95 min, step: 5 min
30 min
A.8
[8-02]
R/W
0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour [E-07]
≠
1
A.8
[8-03]
R/W
20~95 min, step: 5 min
50 min
A.8
[8-04]
R/W
0~95 min, step: 5 min
95 min
A.8
[8-05]
R/W
0: No
1: Yes
A.8
[8-06]
R/W
0~10°C, step: 1°C
3°C
A.8
[8-07]
R/W
[9-03]~[9-02], step: 1°C
18°C
A.8
[8-08]
R/W
[9-03]~[9-02], step: 1°C
20°C
A.8
[8-09]
R/W
[9-01]~[9-00], step: 1°C
35°C
A.8
[8-0A]
R/W
[9-01]~[9-00], step: 1°C
33°C
A.8
[8-0B]
13
A.8
[8-0C]
10
A.8
[8-0D]
16
A.8
[9-00]
R/W
37~depending on outdoor unit, step: 1°C
55°C
A.8
[9-01]
R/W
15~37°C, step: 1°C
25°C
A.8
[9-02]
R/W
18~22°C, step: 1°C
22°C
A.8
[9-03]
R/W
5~18°C, step: 1°C
5°C
A.8
[9-04]
R/W
1~4°C, step: 1°C
1°C
A.8
[9-05]
R/W
15~37°C, step: 1°C
25°C
A.8
[9-06]
R/W
37~depending on outdoor unit, step: 1°C
55°C
A.8
[9-07]
R/W
5~18°C, step: 1°C
5°C
A.8
[9-08]
R/W
18~22°C, step: 1°C
22°C
A.8
[9-09]
R/W
3~10°C, step: 1°C
5°C
A.8
[9-0A]
R/W
3~10°C, step: 1°C
5°C
A.8
[9-0B]
R/W
0: Quick
1: Slow
A.8
[9-0C]
R/W
1~6°C, step: 0,5°C
1 °C
A.8
[9-0D]
R/W
0~8, step:1
0 : 100%
1~4 : 80~50%
5~8 : 80~50%
6
A.8
[9-0E]
6
A.8
[A-00]
0
A.8
[A-01]
0 (*5)
3 (*6)
Room temperature hysteresis.
Pump speed limitation
--
--
--
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
What is the desired delta T in heating?
What is the desired delta T in cooling?
What emitter type is connected to the main LWT zone?
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
--
--
--
Anti-recycling time.
Booster heater delay timer.
Additional running time for the maximum running time.
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
Domestic hot water booster heater hysteresis.
How many leaving water temperature zones are there?
--
--
--
Maximum running time for domestic hot water operation.
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
What is the maximum temperature setpoint?
Domestic hot water booster heater overshoot temperature.
What is the capacity of the backup heater step 1?
What is the capacity of the backup heater step 2?
--
--
What is the capacity of the bottom plate heater?
--
What is the capacity of the booster heater?
Boiler efficiency
What is the hysteresis to be used in reheat mode?
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
(#) Setting is not applicable for this unit.