Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[E-0B]
R/O
0 (#)
A.8
[E-0C]
0
A.8
[F-00]
R/W
0: Disabled
1: Enabled
A.8
[F-01]
R/W
10~35°C, step: 1°C
20°C
A.8
[F-02]
R/W
3~10°C, step: 1°C
3°C
A.8
[F-03]
R/W
2~5°C, step: 1°C
5°C
A.8
[F-04]
R/W
0: No
1: Yes
A.8
[F-05]
0
A.8
[F-06]
0
A.8
[F-09]
R/W
0: Disabled
1: Enabled
A.8
[F-0A]
0
A.8
[F-0B]
R/W
0: No
1: Yes
A.8
[F-0C]
R/W
0: No
1: Yes
A.8
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
--
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Close shut-off valve during cooling?
What is the pump operation mode?
Pump operation allowed outside range.
Above which outdoor temperature is cooling allowed?
Bottom plate heater ON temperature.
Bottom plate heater hysteresis.
Is a bottom plate heater connected?
--
Is a bi-zone kit installed?
--
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
(#) Setting is not applicable for this unit.