Keypad

 

 

Enter main menu, also acts as "ESC" or "Back" keys

 

 

 

Access help screens and graphs

 

 

 

Erase typing mistakes

 

 

 

Enter menus, values, open windows, 

 

 

 

 

Scroll up, down, left and right 

 

 

 

 

Enter values, select options and make selections

 

 

 

Toggle between positive and negative values and mark check boxes

.  

 

Hot Screens 

 

Many of the keys serve as shortcuts. Here are the main ones:

 

 

Hot Screens: 

 

-Software Version 

 

-Return to standard main screen 

 

-Temperature and Humidity Status  

 

-Curve Status 

 

-Curtain Position  

 

-Bird Scale and Feed Bin Status 

 

-Light Status 

 

-Analog Output Status  

 

-Lock password protected controller 

 

-Scan through Hot Screens for five seconds each

Enter 

Enter 

Menu

 

Help

 

Delete

 

Enter 

+/- 

Help 

Increase/Decrease 

Offset from 

Temperature Setting 

from the Standard 

display only (hold 

both keys) – Defined 

in the 

T

EMPERATURE 

C

URVE 

HELP

 

|

 

SET

 

Содержание Platinum Junior

Страница 1: ......

Страница 2: ...ture industry 3 This warranty will not apply in the following cases i if all components of the product are not originally supplied by ROTEM ii the defect is the result of an act of nature lighting str...

Страница 3: ...Static Pressure 12 1 5 Control Mode 14 1 6 System Parameters 15 2 DEVICE 16 Introduction Levels 16 2 1 Levels of Ventilation 17 2 2 Speed Fan Levels 19 2 3 Vent Curtain Levels 20 2 4 Stir Fan Levels 2...

Страница 4: ...6 Heaters 56 5 7 Radiant Heaters 56 5 8 Alarms 56 5 9 Table of Events 56 5 10 History View 57 6 TEST 58 6 1 Switches Relays 58 6 2 Switches Relays Ext 58 6 3 Alarm 59 6 4 Analog Sensors 59 6 5 Digita...

Страница 5: ...l l 8 INSTALL 70 8 1 Setup 70 8 2 Relay Layout 71 8 3 Analog Sensors 72 8 4 Digital Sensors 74 8 5 Analog Output 74 8 6 Curtain Setup 75 8 7 Temperature Definition 76 8 8 Fan Air Capacity 76 8 9 House...

Страница 6: ...ed clocks provide additional channels for greater capability Besides advanced Cool Pad methods you benefit from superior stir fan programs to recover ceiling heat and many other features For the addit...

Страница 7: ...ll move to Level 5 or Level 7 to maintain the Target Temperature Note the Diff F column in this example the Differential Temperature for each level is Zero This means that all these levels occur at th...

Страница 8: ...and negative values and mark check boxes Hot Screens Many of the keys serve as shortcuts Here are the main ones Hot Screens Software Version Return to standard main screen Temperature and Humidity St...

Страница 9: ...pate in the average calculation NOTE Go to the USENSOR READINGSU section to view all the possible sensors 2 Reports the current average temperature This example is in Celsius but yours may be in Fahre...

Страница 10: ...ges they each appear in turn Main Menu Icons Set calibrate and test Bird Scale and Feed Bin Scale Control temperature humidity ventilation static pressure and system parameters Define settings of all...

Страница 11: ...ve growth day type the day number followed by the key UTargetU Set the desired temperature UHeatU Set the temperature to stop heat UTunnelU Set the temperature for Tunnel to begin U Alarm Low HighU Se...

Страница 12: ...iant Heaters can operate at any temperature or level below Tunnel UCool Down Factor U Minimum percentage correction towards target during each increase Uventilation level delayU If average temperature...

Страница 13: ...on for the Radiant Ignition Time with the Radiant Low Heaters to ensure proper heater ignition URadiant Ignition Time sec U Set number of seconds to power radiant ignition Default 30 Note The Heater T...

Страница 14: ...el may come back down automatically UDayU Growth day Can set multiple programs for same day Max programs 20 UHumidityU Humidity at which to begin treatment UInterval MinuteU Number of minutes between...

Страница 15: ...level as litter conditions deteriorate and the birds require greater amounts of fresh air You may also restrict the maximum level to prevent excess air flow on young birds There are three methods for...

Страница 16: ...t in UCONTROL Temperature CurveU to switch minimum level from Min to Soft Min UTemp Choice for Soft MinU Select inside outside attic temperature to control Minimum Level changes The minimum level adju...

Страница 17: ...sure If it exists the outside temperature sensor controls this feature otherwise the average temperature does ULow Static Pressure AlarmU Set alarm for low static pressure If you disable it by setting...

Страница 18: ...emperature for static pressure control UIncoming Air High Temp Deg U Define high temperature for static pressure control UEmergency Static Pressure Delay sec U Set length of time in seconds before ini...

Страница 19: ...which type of min max level method to use UHouse ModeU Select whether the house is in one of the brood set ups or in full house UEmpty House ModeU Select YES in order to disable alarms UTemperature C...

Страница 20: ...SYSTEM PARAMETER 7 1 1 Temperature Curve HELP SET 8 1 1 Radiant Heaters HELP SET 9 1 2 Humidity Treatment HELP SET 11 1 3 Min Max Level Day Soft Min 13 1 4 Static Pressure HELP SET 18 2 1 Levels of V...

Страница 21: ...80 seconds for increase and 60 seconds for decrease The factory default values bias the Platinum slightly toward warmer temperatures as would be appropriate for young birds The level increase delay is...

Страница 22: ...t to 0 b If the ventilation level is below tunnel the differential temperature is relative to Target temperature given in UCONTROL Temperature CurveU c If the ventilation level is a tunnel level the d...

Страница 23: ...t tunnel mode UTunnel Exit Outside Differential from TunnelU The outside temperature must read below this Tunnel Differential to allow exit from tunnel mode UIncrease Level Delay Time sec U Set length...

Страница 24: ...e speed in for up to four groups of fans by level Configure them in UInstall Analog OutputU You will need an optional Analog Output card in your controller This card sends a low voltage control signal...

Страница 25: ...o any output stages the Curtains section will be hidden 3 UMinimum Position Tunnel VentilationU Set position for the tunnel curtain by level If you have Static Pressure in Tunnel turned on UControl St...

Страница 26: ...Attic Operate Until DayU Set the last day for attic operation Attic vents take precedence over side vents However if the pressure is too high with the Attic Vents at 100 open the Platinum automatical...

Страница 27: ...n in percentages UStir FanU Control stir fans according to Continuous Cycle On Cycle Off ventilation cycles are the same as previously set in ULevels of VentilationU Note The Stir Fans operate accordi...

Страница 28: ...ROGRAM HELP SETU U A minimum ventilation U This program helps mixing minimum ventilation air for buildings having stir fans to mix the air coming in with warm inside air UB sensors diff temp U This pr...

Страница 29: ...in seconds from the end or start of cycle you chose in UOperate after end of cycleU above for the stir fans to operate UTime for operation sec U Define length of time in seconds for the stir fans to...

Страница 30: ...Cycle Delay 5 Seconds Operation Duration 20 Seconds Example 2 of Program A Reference at Start of Cycle Delay minus 5 seconds Operation Duration 50 seconds OFF ON OFF Ventilation Cycle Operate after e...

Страница 31: ...gth of time in seconds you would like the stir fan to operate during the cycle UCycle Off time sec U Define the length of time in seconds you would like the stir fan to be off during the cycle NOTE Th...

Страница 32: ...rom day 7 to day 14 the cool pad will continue to work according to day 7 settings from growth day 7 through growth day 14 UTunnel DifferentialU Set difference from tunnel temperature to use this sett...

Страница 33: ...length of time in minutes for flushing If you enter a setting the Platinum applies the flush without regard to ventilation level or operating mode UDiff Between Cool Pads StageU If cool pads are defi...

Страница 34: ...nd TimeU Time of day you want foggers to start and stop o It is possible to set multiple start and stop times for single day o In the screen above the first programmed line is at day 47 The foggers wi...

Страница 35: ...T HELP SET Definitions UTemperature BandU Define the on off hysteresis relative to temperature UHumidity Band U Define the on off hysteresis relative to humidity UMin Level to Enable OperationU Select...

Страница 36: ...the dimmer lights go to 45 There are two periods of dark from 01 00 to 03 00 in the morning and 09 00 PM to midnight This program repeats until day 25 o From day 25 the on off lights stay out and the...

Страница 37: ...over the sunset time The sunset effect starts ahead of the programmed event time by the sunset time so that the controller reaches the target setting at the event time Allow Spiking from Day Set the...

Страница 38: ...NOTE The initial reference time for the Spike Cycle is the end of Sunrise The spike begins Spike Duration minutes before the end of the Spike Cycle and has one minute up and down ramps in intensity I...

Страница 39: ...Check mark water lines to turn on Dot the ones to turn off Feeder Check mark feed lines to turn on Dot the ones to turn off Auger Check mark auger lines to turn on Dot the ones to turn off Note You c...

Страница 40: ...ystem operates On sec On time for the extra system If set to 0 the extra system will not operate at all Off sec Off time for Extra System after completion of on time If you have values in both ON and...

Страница 41: ...ency functions 3 Differential The difference from target temperature at which the device operates during emergency operation 4 Day After this day the device operates continuously without regard to tem...

Страница 42: ...is parameter The card calculates run times between days 1 to 21 Min vent off time day 1 sec Set the off time for minimum ventilation cycle timer during emergency for growth day 1 Min vent on time day...

Страница 43: ...you do not wish to keep separate data simply enter the data into one or the other Initially enter the number of birds placed Thereafter enter the quantity found dead culled Add Culled or moved as fre...

Страница 44: ...enter the menu again If you have installed load cells and connected feed bin scales to your Platinum it will automatically maintain feed inventory including delivery dates and feed consumption data Yo...

Страница 45: ...ssible to enter negative growth days up to 2 If you reset the growth day for a new flock using this tool your old history data will not clear Use the New Flock function to clear out old history in pre...

Страница 46: ...a sensor may have to be considered a valid sensor reading Sensor readings above this are rejected This generates a sensor out of range alarm This does not apply to the special Circuit Breaker Sensor o...

Страница 47: ...These generate an alarm on low feed conditions Allow Feed Alarm From Set time after which controller may send feed shortage alarm Allow Feed Alarm To Set latest time after which controller may not sen...

Страница 48: ...lights are out Quantity for Shortage Minimum flow rate that must be maintained or a water shortage alarm will occur Shortage Alarm Delay Minimum period of time that the shortage must extend through b...

Страница 49: ...er an emergency pressure or feed overrun incident If the controller experiences a high pressure alarm for too long it enters emergency pressure operation by opening all known air sources Curtains open...

Страница 50: ...Platinum has six options besides controller failure or power off to activate the fail safe relay Check the additional settings to apply by using the key High Temperature Select to trigger fail safe wh...

Страница 51: ...ontroller and make changes to all controller settings and their own password A user can see and change only his own password The visitor can access the controller but cannot make changes Each time som...

Страница 52: ...Us se er r M Ma an nu ua al l 4 SCALE 4 1 Scale Layout Use Scale Layout to define the scales or feed bins connected to the controller 1 Scale Layout Example Scale layout Enter weighing device attache...

Страница 53: ...set Lower values mean increased precision at the expense of frequency of adjustment With larger values the tare adjustment is made more frequently Default 3 Weighing Sens 1 Low 10 Hi This parameter a...

Страница 54: ...ime Set the hour you would like the scale to stop weighing Upper Range 0 100 Band above reference weight Lower Range 0 100 Band below reference weight Reference Weight 1 Starting out weight for scale...

Страница 55: ...ight Amount required to be filled during refill in order to be recorded in the HISTORY Default 2000 Kg Filling Detection Weight Set the weight you want your controller to detect a filling Resume Time...

Страница 56: ...a for each scale If you select MIXED weighing the history includes Average data for all birds and separate male and female data for scale 1 and also for scale 2 Use the arrow keys to scroll to the sep...

Страница 57: ...Reports the amount of feed is converted into the bird s weight 4 8 Test This section is a real time table to show the status of all scales connected to the controller Make sure that status for all are...

Страница 58: ...LE E D Do oc c N Na am me e U Us se er r M Ma an nu ua al l 4 9 Calibration Calibrate the scales connected to the controller 9 Calibration Choose scale to calibrate Instructions on screen Good Calibra...

Страница 59: ...s Junior P PA AG GE E 5 54 4 C CH HA AP PT TE ER R S SC CA AL LE E D Do oc c N Na am me e U Us se er r M Ma an nu ua al l FEED BIN CALIBRATION Scale Instructions on screen Instructions on screen Good...

Страница 60: ...onsumption and shows the daily differential change from the previous day in percent You must have the water monitor digital inputs connected You can monitor up to two drinking water meters total drink...

Страница 61: ...rm Alarms that are currently activate show as flashing in the screen The alarm history does not erase with the New Flock function under Management Growth Date Flock The last 250 alarms are saved and a...

Страница 62: ...he minute or only on a daily basis Factory default collects one hour data on a selection from the choices below Under Help GRAPH you can select a variety of graphs of the detailed history In the HISTO...

Страница 63: ...controller Use this option to determine faulty hardware NOTE Reverse video indicates switches are ON in automatic mode Moreover the controller can operate a relay only if it is in Auto state 6 2 Switc...

Страница 64: ...m That is the Normally Open side is Closed during NO ALARM for example 6 4 Analog Sensors Observe the converter readings for analog sensors with this menu The readings can vary from 0 to 1023 The valu...

Страница 65: ...open input to each channel can be done and observing the response on the display is available 6 6 Analog Output Use this manual to test variable speed fans and light dimmers You can immediately enter...

Страница 66: ...that has been identified by the Plug and Play system The system detects all cards except Communication The standard optional Communication card provides lightning protection and does not have local co...

Страница 67: ...ference sensors and a pail of water at the approximate temperature desired 2 Stir the reference sensor together with the Platinum sensor vigorously in the bucket of water Keep hands off the sensor its...

Страница 68: ...M Ma an nu ua al l 7 2 Humidity Calibration To calibrate obtain a suitable humidity test kit and use the procedures described there They are commonly available via the World Wide Web Adjust the Platin...

Страница 69: ...are calibration 130 40 Hardware calibration Adjust trimmer Calibrate the static pressure physically using the calibration screw on the sensor card prior to completing the software calibration Hardware...

Страница 70: ...digital monitoring device may generate a dry contact pulse for each quantity of feed or it may simply indicate that the feed is running 2 Enter the quantity of feed per pulse in case you use a dry co...

Страница 71: ...ior P PA AG GE E 6 66 6 C CH HA AP PT TE ER R S SE ER RV VI IC CE E D Do oc c N Na am me e U Us se er r M Ma an nu ua al l 7 6 Vent Calibration This option enables the user to calibrate the vent Enter...

Страница 72: ...ater line 1 through 122 Water line 10 individual water line supplementary to select the line to flush During normal operation only relay 111 water main is active During flushing relay code 112 is acti...

Страница 73: ...er Line Lift Inch define the specific drinker line lift measured in inches FEEDERS DRINKERS HELP SET Adjust at time Set the desired time to adjustment FEEDER WINDOW Stop feed before adjust min Set how...

Страница 74: ...7 10 Read from Plug This menu allows the user to read a saved program from a data plug into the controller quickly and reliably rather than inserting all the settings information manually NOTE Make s...

Страница 75: ...uage English Temperature Unit Celsius Fahrenheit Static pressure unit Milibar Inches of WC water column Pascal cm of WC mm of WC none Fan air capacity unit Cubic feet per minute CFM Cubic meter per ho...

Страница 76: ...wn cursor keys Code 100 and above use the keys before selecting the choice and then press a 2 digit number In order to duplicate relays use the As Relay X where X stands for a relay number defined alr...

Страница 77: ...e and humidity sensors and circuit breaker as Analog sensors These sensors measure a continuous range rather than just on or off HELP button on touch pad Set parameters Define relay operation mode DC...

Страница 78: ...nel Fan 53 62 Exhaust Fan 63 77 Stir Fan 78 81 Cool 82 85 Cool Pad 86 89 Fogger 90 97 Curtain 98 101 Extra System 102 103 Tunnel Curtain 104 105 1st Inlet 106 107 2nd Inlet 108 109 Water 110 111 Feede...

Страница 79: ...on off and pulsing inputs such as auxiliary alarms pulsing water meters and feed 8 5 Analog Output This selection controls light dimmers and variable speed fans Select the desired Output Function from...

Страница 80: ...at a time in order to calibrate their position counters Whenever any curtain reaches one of the limits its calibration counter automatically resets Delay between stages minutes for natural curtains Wh...

Страница 81: ...xhaust Fans Tunnel Fans Feed and Light do not appear Note that Exhaust Fans and Tunnel Fans do not appear because the Ventilation Levels defined in Device Levels of Ventilation control their operation...

Страница 82: ...is a measure of the communication speed for local or remote communications to a PC The default is 9600 represents a data rate of approximately 1000 characters per second If the connection fails at thi...

Страница 83: ...PPENDIX SENSOR READINGS SENSOR DEFINITION Temp Displayed with the specific sensor number Out T Outside temperature Press Pressure Hum In Inside humidity Hum Out Outside humidity Weight Average weight...

Страница 84: ...ng tunnel fan number Exh Fan Indicates operating exhaust fan number Stir Indicates operating stir fan number Cool P Indicates operating cool pad number Fogger Indicates operating fogger number Inlet T...

Страница 85: ...urve HELP SET parameter House mode Control Mode HELP SET parameter Level Level number Tunnel Natural Min Vent The controller s state Fan Off How long the cycle ends its operation Fan On How long the c...

Страница 86: ...ars when the digital card fails Memory restore Appears when the system does restore cause by noises Minimum ventilation Appears when minimum ventilation occurs Natural ventilation Appears when enterin...

Страница 87: ...User 1 5 pass Appears when the user changed his password Change Owner pass Appears when the owner changed his password Data read from plug Appears when data is being read from plug System recover Appe...