Overflow At Dark (Per minute):
Select the overflow limit – when it is
dark, for the controller to check every minute.
Overflow Alarm Delay (minute):
Define the amount of time for the
controller to wait before generating an overflow alarm.
Extra Delay At Light Start (min)
:
when the first light appears, define
the amount of time before the controller begins to operate according to
the set Overflow for that day.
o
Water shortage alarms:
Minimum amount in the delay period.
Allow Water Shortage Alarm From:
Time after which controller may
generate water shortage alarms.
Allow Water Shortage Alarm To:
Time after which controller may
NOT
generate water shortage alarms.
Shortage During Lights Off:
Select whether water shortage alarm
should be disabled when all lights are out.
Quantity for Shortage:
Minimum flow rate that must be maintained or
a water shortage alarm will occur.
Shortage Alarm Delay:
Minimum period of time that the shortage must
extend through before generating an alarm.
o
Bird scales alarms:
Time restrictions on scale alarms.
Allow Bird Scale Alarms From:
Time for which the controller will begin
generating alarms for the bird scale.
Allow Bird Scale Alarms To:
Time after which controller may not
generate bird scale alarms.
o
Auxiliary alarms:
Assign auxiliary alarms in Install menu. Note that digital
sensors, aux. alarm input with related relay must always match their relay status.
Related Relay For Aux Alarm 1:
Relay for Auxiliary Alarm 1.
Related Relay For Aux Alarm 2:
Relay for Auxiliary Alarm 2.
Related Relay For Aux Alarm 3:
Relay for Auxiliary Alarm 3.
Related Relay For Aux Alarm 4:
Relay for Auxiliary Alarm 4.
AUX. Alarm Delay (sec)
: Separate from the
Global Alarm Delay
, once
there exists a dry contact the alarm will be sent after the defined
AUX.
Alarm Delay
.
o
Circuit breaker alarm:
Set circuit breaker alarm temperature.