Alarm Setting
•
Global Alarm Delay (sec):
Alarms without a separate alarm delay, use this global
delay before signaling the alarm.
•
Alarm Reminder (min., 0-Disable):
Set a reminder after a period of time in minutes if
the situation has not yet been corrected.
SENSOR ALARM
•
Sensor Low Temperature Range:
sets the minimum reading a sensor may have to be
considered a valid sensor reading. Sensor readings below this are rejected. This
generates a sensor out of range alarm. This does not apply to the special Circuit
Breaker Sensor or Outside Temperature Sensor.
•
Sensor High Temperature Range:
sets the maximum reading a sensor may have to
be considered a valid sensor reading. Sensor readings above this are rejected. This
generates a sensor out of range alarm. This does not apply to the special Circuit
Breaker Sensor or Outside Temperature Sensor.
•
Sensor Alarm-Differential from Low Alarm:
individual sensor (or zone) alarm if any
active sensor reads this much or more below the
Control | Temperature Curve | Low
•
Sensor Alarm-Differential from High Alarm:
individual active growth area sensors
alarm if they read this much or more above the
Control | Temperature Curve | High
ALARM
•
Alarm Test at Time:
schedule an alarm test at a particular time.
•
Day of Alarm Test:
choose from Daily or a particular day of the week for the scheduled
alarm. You can choose this to precede a weekly generator test by a brief period.
•
Alarm Test Duration (sec):
choose a specific duration for the Alarm Test.
5. Alarm Setting
Enter
Menu
NOTE: