HELP | SET Definitions:
•
Diff above target for emergency:
Set a value above temperature target, at which the
emergency card enters emergency operation.
•
Diff below target for emergency:
Set a value below temperature target, at which the
emergency card enters emergency operation.
•
Min. vent on time day 1 (sec):
Set the run time for 1 day old birds in this parameter.
The card calculates run times between days 1 to 21.
•
Min. vent off time day 1 (sec):
Set the off time for minimum ventilation cycle timer
during emergency for growth day 1 .
•
Min. vent on time day 21 (sec):
Set the on time for minimum ventilation for three week
birds.
•
Min. vent off time day 21 (sec):
Set the off time for minimum ventilation cycle timer
during emergency for growth day 21.
•
Delay time to start fans (sec):
Set a delay time for the card to wait upon entering
emergency before starting fans. This delay gives air inlet devices time to pre-position
before fans turn on and build static pressure. Otherwise the static pressure could cause
air inlet curtains to stick to wire mesh barriers.
Enter
Help