PROGRAM B (sensors diff temp)
•
U
Temp Diff to operate
U
:
Set the degree of difference between sensors for stir fans to
begin operating.
•
U
Diff between sensor number
U
:
Select a sensor to define one temperature reading.
•
U
Diff between sensor number
U
:
Select a second sensor to define a temperature reading
from a different area.
•
U
Cycle On time (sec)
U
:
Define the length of time in seconds you would like the stir fan to
operate during the cycle.
•
U
Cycle Off time (sec)
U
:
Define the length of time in seconds you would like the stir fan to
be off during the cycle.
NOTE:
The other parameters are explained in PROGRAM above.
PROGRAM C (for heaters)
•
U
Diff below target to operate
U
:
Set the degree of difference below the target
temperature for stir fans to operate.
NOTE:
Additional parameters are the same as in PROGRAMS A & B, explained above.
PROGRAM D & E (independent)
These two programs allow you to set the desired cycle, level range, and time range for
the stir fans to operate. They do not rely on ventilation cycles or temperature readings,
thus making them independent.