EVELS OF
V
ENTILATION
HELP
|
SET
HELP | SET Definitions:
•
U
Maximum Levels of Ventilation
U
:
Set the maximum amount of levels desired.
•
U
First Tunnel Level
U
:
Entry point to tunnel mode.
•
U
Max Fans, Switch to Tunnel
U
:
Maximum amount of fans allowed to work while entering
tunnel mode.
•
U
Tunnel Exit – Differential from Tunnel
U
:
Set degree of difference below Tunnel temp
(set in
Control | Temperature Curve
) to exit tunnel mode.
•
U
Tunnel Exit – Outside Differential from Tunnel
U
:
The outside temperature must read
below this ( Differential) to allow exit from tunnel mode.
•
U
Increase Level Delay Time (sec)
U
:
Set length of time in seconds before transitioning to
next level.
•
U
Decrease Level Delay Time (sec)
U
:
Set length of time in seconds before reducing to
lower level.
•
U
Fan Cycle Time (sec)
U
:
If set to 0, then set on and off times for each level manually. If
you are using a fixed cycle time, such as 300 seconds, enter it here and then you need
to enter only the on time at each level. Default: 0
•
U
Tunnel Exit Delay (minutes)
U
:
Set length of time in minutes before exiting tunnel mode.
This time begins once all other parameters are satisfied.