Rotar Giga 75-100 - Cod.197AA3900 - Rev.03 - 05/2007

GB

11

11

11

11

11

FIRST START-UP

Before starting the machine for the first time, make sure that:

the power supply voltage corresponds to the voltage indicated on the CE plate

the electrical connections have been made using adequately sized cables

the master switch (on the wall) has suitable fuses

the oil level is higher than the minimum (where necessary, fill using oil of the same type)

the air outlet cock is completely open.

The first start-up of the compressor must only be carried out by a specialised technician.

Press the 

  button:

If the machine does not start and the message “rot.dir.error” appears on the display:
switch off the electrical power using the wall switch, open the electrical cabinet door and invert the position of two phases in the

terminal block, close the door, restore voltage and restart the machine.

If the machine starts on the first try:

display status at start-up (remains for 5 seconds)

display status during normal operation

Line 1
Default display

“——screw.temp.” = temperature of the screw.

Using 

  you can view the following information:

Inside temp.

indicates the temperature inside the electrical compartment

——air.temp.

indicates the temperature of the air at outlet

——total hours

indicates the total working hours

—load hours

indicates the working hours with load

—idle hours

indicates the idle running hours

maint.hours

indicates the hours remaining until maintenance is required

air filter h.

indicates the hours remaining until air filter replacement is required

bearing.lubric.

indicates the hours remaining until lubrication of the bearings is required

oil filter h.

indicates the hours remaining until oil filter replacement is required

starts/hour

indicates the number of starts recorded in the last hour

After 25 seconds without any buttons being pressed, the default display returns.
Line 2
Indicates the pressure inside the screw compressor.
Line 3
Compressor status:
IDLE

idle running

LOAD

the compressor is loading

STAND-BY

waiting for start command

REMOTE-OFF

waiting for remote start command

OFF

the compressor is powered but not operating

Line 4
DATE AND TIME

if a start-up has been programmed, a blinking clock appears in the lower right-hand corner.

START/STOP CYCLE

Pressing the  

  button

1.

Stand-by for start-up: the message (STAND-BY) is displayed: if the compressor was switched off, there will be a pause of

15 seconds before the cycle starts; otherwise, the compressor remains in stand-by until the request for air comes from the
pressure transducer.

2.

Start: the compressor is started in “star” configuration and the message (IDLE) is displayed.

3.

Run: after six seconds, the configuration changes from star to delta.

After a few seconds, if requested by the transducer, the load solenoid valve is energised and the message (LOAD) is displayed.

Pressing the 

 button

the load solenoid valve enable is interrupted; the idle cycle starts and the message (IDLE) is displayed blinking. At the end of

the idle cycle, the compressor switches off and the message “OFF” is displayed.

START-UP PROCEDURE AND DISPLAY INFORMATION

date

software

release

Easy Tronic III

V.1.0.5  dd/mm/yy

Easy Tronic III

--screw.temp:065°C

06.5Bar

STATUS=OFF

time..... date.....

Содержание Giga 100

Страница 1: ...Rotar Giga 75 100 Cod 197AA3900 Rev 03 05 2007 GB use maintenance MANUAL Rotar Rotar Rotar Rotar Rotar Giga 75 100 Giga 75 100 Giga 75 100 Giga 75 100 Giga 75 100...

Страница 2: ......

Страница 3: ...1 oil drain tube no 1 door key no 1 user s guide CONDITION OF THE MACHINE WHEN SUPPLIED Every compressor is shop tested and delivered ready to be installed and to be set at work The oil used is RotEn...

Страница 4: ...ce and maintenance carried out so far SYMBOLS USED IN THE MANUAL Some symbols are used to highlight danger situations give recommendations or information These symbols are usually positioned next to t...

Страница 5: ...CE plate Always follow the maintenance schedule specified in the user s guide WHAT NOT TO DO Do not touch inner parts and pipes as they are very hot during compressor operation and stay hot for a cer...

Страница 6: ...tion of the machine Open the access doors and check all inner parts visual check Dispose of the packaging in compliance with the current waste disposal regulations PLACEMENT fig 2 The room chosen for...

Страница 7: ...the compressor heat energy as auxiliary heating unit These pipes should not be longer than 4 m Otherwise an auxiliary fan should be installed on the outlet side POWER CONNECTION Proceed to power conne...

Страница 8: ...takes you to the menu of operating parameters In certain cases a password is required in order to access the modifications Use the buttons to scroll the menu 0 Control unit ID service password selects...

Страница 9: ...ssure assistance password enabling this parameter the visualisation of the pressure and respective alarms is maintained but the control of the start of the compressor takes place using an external pre...

Страница 10: ...t verify the cause and then press the RESET button XX Emergency button Alarm tripped when the emergency button is pressed which blocks compressor operation To silence the alarm first reset the emergen...

Страница 11: ...filter replacement is required bearing lubric indicates the hours remaining until lubrication of the bearings is required oil filter h indicates the hours remaining until oil filter replacement is re...

Страница 12: ...il is returned to filter 11 through tube 10 From filter 11 oil reaches compressor 3 through tube 12 Oil is mixed with sucked air to form an air oil mixture that provides sealing and lubrication of com...

Страница 13: ...light for possible cuts replace element if any CHANGE THE AIR FILTER ELEMENT EVERY 3000 HOURS Undo retaining screws 3 from support panel 4 and remove prefilter Wash with water and soapy solution Fully...

Страница 14: ...ion fig 12 To perform this check you need a special measurement instrument that that provides a precise indication of the level of tension of the belt by means of a frequency measurement Proceed as fo...

Страница 15: ...STED OIL IS HIGHLY POLLUTANT Dispose of exhausted oil in compliance with current laws Used oil RotEnergy Plus Different compatible oil see table Service description Operating hours Operating hours Che...

Страница 16: ...emove and clean the intake regulator Oil mist separator filter clogged Replace the oil mist separator filter Line cock closed Open the cock Minimum pressure valve blocked Check and clean the valve if...

Страница 17: ...r no Ambient temperature C Noise level 1 m dB A Max compression temperature C Safety valve setting bar Separator pressure switch setting bar 8 9 10 9 8 9 10 9 Start up pressure switch setting bar Moto...

Страница 18: ...12 13 14 15 15 15 15 16 17 18 19 20 24 L22 L12 2 L31 L11 FU1 3 3 5 6 8 10 HL YV BULBO TERM THERM PROBE YV 5 25 AUTO DRAIN BULBO TERM THERM PROBE 3 3 PL1 PL2 10 8 6 5 12 13 22 021 ST2 BP V P V 021 22 2...

Страница 19: ...n pressure switch SA Radiator fan emergency control BP Line pressure transducer ST1 Screw delivery temperature probe ST2 Outlet air temperature probe D Electronic controller YV Solenoid valve M1 Upper...

Отзывы: