background image

Rotar Giga 75-100 - Cod.197AA3900 - Rev.03 - 05/2007

18

18

18

18

18

WIRING DIAGRAM

V3 W3 U1 V1 W1 W2 U2 V2

L1

L2

L3

U1

W1

V1

W2

U2

V2

L1

L2

L3

V3

W3

LINEA

LINE

MOTORE COMPRESSORE

COMPRESSOR MOTOR

U3

U3

MOTORE VENTILATORE

FAN - MOTOR

RT

21

15

15

22

Predisposizione x collegamento  
controllo pressione remoto

M2

15

+

-

SP1

SP3

NC

+

SB

P

SP2

SB+NC

FR

FU2

FU3

FU4

FU5

FU6

FU7

0

3

3

5

5

6

8

10

12

13

14

15

15

15

15

16

17

18

19

20

24

L22

L12

2

L31

L11

FU1

3

3

5

6

8

10

HL+YV

BULBO TERM.

THERM.PROBE

YV

5

25

AUTO.DRAIN

BULBO TERM.

THERM.PROBE

3

3

PL1

PL2

10

8

6

5

12

13

22

021

ST2

BP

V

P

V

021

22

23

21

+

-

SB+NC

50

11

 HL

11

2

50

14

M1

A: X08 (9)

A: X08 (1)

A: X08 (10)

2

14

1

2

3

4

5

6

7

8

9

D

24

X08

1

2

3

4

5

10

6

1

2

3

4

5

6

7

8

1

2

3

1

2

9

8

7

6

5

4

3

2

1

4

3

2

1

2

2

1

2

2

1

X02

X07

X10

X03

X01

X09

Rs485

X05

PLUG 6

PLUG 8

Rs232

0

12 11

CanBus

Progr.

Com.

Display

ST1

+AUTO.DRAIN

0

15

16

17

18

19

20

22

021

V

V

P

V

21

A : M1

A : M1

KR

12

13

14

_

+

11

2 10

5

6

8

50

Remote pressure control

Содержание Giga 100

Страница 1: ...Rotar Giga 75 100 Cod 197AA3900 Rev 03 05 2007 GB use maintenance MANUAL Rotar Rotar Rotar Rotar Rotar Giga 75 100 Giga 75 100 Giga 75 100 Giga 75 100 Giga 75 100...

Страница 2: ......

Страница 3: ...1 oil drain tube no 1 door key no 1 user s guide CONDITION OF THE MACHINE WHEN SUPPLIED Every compressor is shop tested and delivered ready to be installed and to be set at work The oil used is RotEn...

Страница 4: ...ce and maintenance carried out so far SYMBOLS USED IN THE MANUAL Some symbols are used to highlight danger situations give recommendations or information These symbols are usually positioned next to t...

Страница 5: ...CE plate Always follow the maintenance schedule specified in the user s guide WHAT NOT TO DO Do not touch inner parts and pipes as they are very hot during compressor operation and stay hot for a cer...

Страница 6: ...tion of the machine Open the access doors and check all inner parts visual check Dispose of the packaging in compliance with the current waste disposal regulations PLACEMENT fig 2 The room chosen for...

Страница 7: ...the compressor heat energy as auxiliary heating unit These pipes should not be longer than 4 m Otherwise an auxiliary fan should be installed on the outlet side POWER CONNECTION Proceed to power conne...

Страница 8: ...takes you to the menu of operating parameters In certain cases a password is required in order to access the modifications Use the buttons to scroll the menu 0 Control unit ID service password selects...

Страница 9: ...ssure assistance password enabling this parameter the visualisation of the pressure and respective alarms is maintained but the control of the start of the compressor takes place using an external pre...

Страница 10: ...t verify the cause and then press the RESET button XX Emergency button Alarm tripped when the emergency button is pressed which blocks compressor operation To silence the alarm first reset the emergen...

Страница 11: ...filter replacement is required bearing lubric indicates the hours remaining until lubrication of the bearings is required oil filter h indicates the hours remaining until oil filter replacement is re...

Страница 12: ...il is returned to filter 11 through tube 10 From filter 11 oil reaches compressor 3 through tube 12 Oil is mixed with sucked air to form an air oil mixture that provides sealing and lubrication of com...

Страница 13: ...light for possible cuts replace element if any CHANGE THE AIR FILTER ELEMENT EVERY 3000 HOURS Undo retaining screws 3 from support panel 4 and remove prefilter Wash with water and soapy solution Fully...

Страница 14: ...ion fig 12 To perform this check you need a special measurement instrument that that provides a precise indication of the level of tension of the belt by means of a frequency measurement Proceed as fo...

Страница 15: ...STED OIL IS HIGHLY POLLUTANT Dispose of exhausted oil in compliance with current laws Used oil RotEnergy Plus Different compatible oil see table Service description Operating hours Operating hours Che...

Страница 16: ...emove and clean the intake regulator Oil mist separator filter clogged Replace the oil mist separator filter Line cock closed Open the cock Minimum pressure valve blocked Check and clean the valve if...

Страница 17: ...r no Ambient temperature C Noise level 1 m dB A Max compression temperature C Safety valve setting bar Separator pressure switch setting bar 8 9 10 9 8 9 10 9 Start up pressure switch setting bar Moto...

Страница 18: ...12 13 14 15 15 15 15 16 17 18 19 20 24 L22 L12 2 L31 L11 FU1 3 3 5 6 8 10 HL YV BULBO TERM THERM PROBE YV 5 25 AUTO DRAIN BULBO TERM THERM PROBE 3 3 PL1 PL2 10 8 6 5 12 13 22 021 ST2 BP V P V 021 22 2...

Страница 19: ...n pressure switch SA Radiator fan emergency control BP Line pressure transducer ST1 Screw delivery temperature probe ST2 Outlet air temperature probe D Electronic controller YV Solenoid valve M1 Upper...