26
--
11) MAINTENANCE PROGRAMME --
This programme indicates all the necessary periodic operations to be undertaken in the machine and which
are essential to ensure its efficient function and long life.
ORDINARY MAINTENANCE
Can be undertaken by the personnel who operate on the machine and includes all those periodic
programmed maintenance operations such as checks on the oil level, air filters, refuelling, cleaning
operations and checks to isolate any eventual leakage of lubricant or fuel inside the machine.
Here follows a list of all the operations relating to the compressor part, in order of frequency, while for those
relating to the "motor" please refer to the USER AND MAINTENANCE MANUAL, supplied by the motor
construction company with the machine.
--
11.1) DAILY CHECKS --
-- 11.1.1) DAILY AND BEFORE STARTING UP THE MACHINE --
- Check on the compressor oil level (paragraph 12.1).
- Check for any lubricant leakage.
-- 11.1.2)
DAILY AND WITH MOTOR RUNNING --
-
Check on all the indicator lights positioned on the control panel
- Check on the maximum pressure level
- Check on the minimum pressure level
-- 11.2) WEEKLY --
-
Check on air compressor filter (12.11).
WARNING: Should the compressor operate in a very dusty environment the air filter must be
checked, cleaned or replaced more often than indicated above.
--
11.3) EVERY THREE MONTHS --
- Safety valve efficiency check .
- Oil cooling radiator cleaning (12.6).
- Check on the oil recovery nozzle (12.8).