18

 

 

 
7.4 Display Structure and Menu Navigation 

 
Display Item Structure: 
 
All value, parameter or option selection displays are grouped into menu lists. Items are assigned to a list 
according to type and classification. Items that can be used to select options or modify functions are 
assigned to ‘menu mode’ lists. Items that an operator may require to view during routine operation, detected 
pressure or temperature values for example, are assigned to the normal operational mode list. Lists are 
identified by page number, the normal operational display list is page 0. All parameters and options are 
assigned to menu mode pages 1 or higher. All Page 0 items are view only and cannot be adjusted. 
 
Normal Operational Mode (Page 0): 
 
At controller initialisation, all display elements and LED indicators are switched on for three seconds, the 
display will then show the software version code for a further 3 seconds before initialisation is complete and 
the normal operating display (Page 0) is shown. In page 0 ‘normal operational display mode’ the Display 
Field will show the final delivery pressure continuously and the Item and Value Fields will initially show the 
Information Item display for 35 seconds before reverting to the default temperature display item. All available 
Item and Value field option displays (temperatures, pressures, hours counters) can be selected using the Up 
or Down buttons at any time. The Item display will revert to the default item after 35 seconds if no further 
selection is made. Pressing the Enter button will lock any selected Item display and inhibit return to the 
default display. When an Item display is locked the lock key symbol will slow flash. To unlock an Item display 
press Up or Down to view an alternative Item display or press Reset or Escape. In page 0 Escape will select 
the Status Information Item display and Reset will select any active fault code display or the Status 
Information Item display if no faults are active. Unless a selected Item display is locked, the display will 
automatically jump to the Status Information Item display at key status change events. The timeout period 
before returning to the default Item display is modified in some instances to enable the full range of a set 
countdown timer to be shown. No Item values, options or parameters can be adjusted in page 0. If a fault 
condition occurs the fault code becomes the first list item and the display will automatically jump to display 
the fault code. More than one active fault code item can exist at any one time. 
 
Access Code: 
 
Access to page list displays higher than page 0 are restricted by access code. To access menu mode pages 
press UP and DOWN together, an access code entry display is shown and the first code character will flash. 
Use PLUS or MINUS to adjust the value of the first code character then press ENTER. The next code 
character will flash; use UP or DOWN to adjust then press ENTER. Repeat for all four code characters. If the 
code number is less than 1000 then the first code character will be 0(zero). To return to a previous code 
character press ESCAPE. When all four code characters have been set to an authorized code number press 
ENTER. Access to certain menu mode pages is dependent on authority level determined by the access code 
used. An invalid code will return the display to normal operational mode; page 0. 
 
 
 
 
 The following pages and access levels are used: 
 

ACCESS LEVEL = USER 

 (code = 9) 

ACCESS LEVEL = 
SERVICE 1 

(code = 100) 

P00, P01, P02 

 

P00, P01, P02,  

P08 

 

Содержание RVD 40-10

Страница 1: ...re es ss so or r w wi it th h e el le ec ct tr ro on ni ic c c ca ar rd d A Ai ir rm ma as st te er r S S1 1 RVK RVK 25 RVK 30 RVK 40 Via Bernezzo 67 12023 CARAGLIO CN ITALIA TLF 39 0171 619676 FAX 3...

Страница 2: ...itten authorization of ROTAIR The illustrations descriptions references and technical data container in the present manual are purely for reference purposes only and are not binding ROTAIR reserves th...

Страница 3: ...instruction 10 Safety devices 11 Program maintenance 12 Checking and maintenance ATTENTION The failure to follow or apply the instructions or regulations indicated in the present manual with result in...

Страница 4: ...ORKING PRESSURE bar YEAR OF CONSTRUCTION ACOUSTIC POWER dB A 100 Measured in accordance with ISO 1217 standards 5 Measured in accordance with directive CEE 84 533 technical adaptation 85 406 CEE CAUTI...

Страница 5: ...del rated rated ISO 1217 ISO 1217 Frequency Pressure Pressure power power kW HP lt min cfm Hz bar psi RVK 25 8 18 5 25 3100 110 50 8 114 RVK 25 10 18 5 25 2700 96 50 10 143 RVK 25 12 18 5 25 2300 81 5...

Страница 6: ...nforming and will release the manufacturer from any further responsibility which will fully that of the user itself Conforming use presupposes the observance of the following regulations concerning th...

Страница 7: ...tact with incoming air 7 Before proceeding to disassemble any pressurized component the compressor or the machine needs to be suitably isolated from all pressure sources and should be totally exposed...

Страница 8: ...a risk of machine overheating 7 When selecting flexible hosing to connect the machine to the tool it is important to ensure that they are of the correct dimensions in terms of length the air volume i...

Страница 9: ...ulsations and compression comes about axially The engine and the compression unit are linked by means of a belt transmission system chap 5 6 The oil tank is integrated on the same compression unit on...

Страница 10: ...e followed by the load delay time is executed before loading In the event of a motor stop initiated by a stop command or when entering standby mode a blow down timer adjustable is started If a start r...

Страница 11: ...n inhibit fault code is displayed when triggered but is not recorded in the fault log Alarm Fault A An alarm fault is a warning condition that does not present an immediate danger or potential damage...

Страница 12: ...Information Item display Standby Run On Time When off load the standby run on timer will start If the compressor remains in an off load condition and the timer expires the main motor will stop and th...

Страница 13: ...reached OR unload request shutdown error NO shutdown error shutdown error standby run on time expired load request 1 2 3 4 7 8 10 load load delay expired 9 stop run on time stop run on time expired 12...

Страница 14: ...ed for any other purpose Reset will initiate a display jump to the fault code item if a fault condition remains active or initiate a display jump to the information item if no active faults exist in n...

Страница 15: ...ished continuously Machine State Number Machine State Status Fault 1 Shutdown Error OFF FF 2 Startup Init OFF OFF Start Inhibit Check OFF 3 Start inhibit condition OFF SF 4 Ready to Start OFF OFF 5 Bl...

Страница 16: ...f selected item fault condition Symbolic status information in normal operational mode Information Screen item Bottom Item and Value Field Item identification 2 character alphanumeric 14 segment Item...

Страница 17: ...ailure autorestart enabled optional function Remote load or remote pressure regulation active Remote start stop Normal Operational selected item locked as temporary default display Menu Mode page item...

Страница 18: ...ock key symbol will slow flash To unlock an Item display press Up or Down to view an alternative Item display or press Reset or Escape In page 0 Escape will select the Status Information Item display...

Страница 19: ...ed by pressing ESCAPE Page 3 Page 2 Page 1 Item 1 Value Item 2 Value Item 3 Value Item 4 Value Item 5 Value Page 0 Item 1 Value Item 2 Value Item 3 Value Item 4 Value Item 5 Value Item 6 Value Page 5...

Страница 20: ...me P press units bar psi kPa T temp units o C o F So mini sequencer operation Sr mini sequencer rotation time 01 logged error 1 to 15 logged error 15 P01 Operation Access Code only shown if internal p...

Страница 21: ...edit 0 0 100 0 SP 100 0 only shown if internal pressure sensor function activated only shown if variable speed regulation mode is activated S1 20 only Status Information Item The page 0 Status Informa...

Страница 22: ...stop run on time s 1 1 60 30 St 30 s 7 blowdown time s 1 1 600 10 Bt 10 s 8 pressure units 1 0 2 0 P 0 0 bar 1 psi 2 kPA 9 temperature units 1 0 1 0 T 0 0 0 C 1 0 F 10 mini sequencer operation 1 0 1 0...

Страница 23: ...oad state the controller will maintain speed at the set offload speed setting If pressure remains above the load pressure set point for longer than the set run on time the main motor will stop and the...

Страница 24: ...and will not stop the compressor once started and in the started state Start inhibit conditions are not checked during an automated motor start from Standby Run inhibits are fault states that prevent...

Страница 25: ...ut number for controller input terminal location input location number input location description 0 digital input 1 analogue input 2 to 7 not used 8 special functions 9 special functions slave unit fa...

Страница 26: ...cy while for those relating to the motor please refer to the USER AND MAINTENANCE MANUAL supplied by the motor construction company with the machine 11 1 DAILY CHECKS 11 1 1 DAILY AND BEFORE STARTING...

Страница 27: ...to the amount of dust in the working environment Every 2000 HOURS Compressor oil replacement 12 2 Every 2000 HOURS Oil separator element replacement 12 4 Every 2000 HOURS Cloth replacement in oil sepa...

Страница 28: ...r at least once a year To change the oil proceed as follows 1 Change the oil when the machine is hot 2 switch off the compressor and disconnect the main switch 3 Unscrew the oil plug on the tank side...

Страница 29: ...condition of the recovery nozzle described in and having made sure of the correct oil level in thank should there be any further traces of oil in the compressed air it is necessary to replace the oil...

Страница 30: ...ontained inside using the special tap see paragraph on compressor oil replacement Now loosen the flange of the oil separator tank part 1 fig 7 Unscrew the filter part 2 fig 8 using a 62 mm spanner and...

Страница 31: ...lly open the air cock the pressure of between 4 5 5 bar must appear on the gauge Should a different pressure appear than that indicated above proceed with setting as follows fig 10 3 Release the lock...

Страница 32: ...and therefore to avoid soiling the operator and the inside of the machine it is advisable to bind the valve with a cloth If the pin fail to rise after being guided with the pliers thereby preventing...

Страница 33: ...for air suction and a second duct for letting hot air out Both ducts shall be connected with the outside and set in such a way as to prevent suction air from mixing with exhaust air They shall have an...

Страница 34: ...10 15 and of 50 63 N for RVK 20 If the arrow value f exceeds the indicated value it means that the belts are slack while if the value is lower than this it means that the belts are too taut Warning Be...

Страница 35: ...part A fig 16 2 Rotate the regulation screw part B fig 16 for tensioning 3 If the belts have been replaced it is necessary to tension them to the correct value proceeding as described at point 1 of t...

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...62 9881 S 1 14 SUPPORT PANEL PRE FILTER 124 2070 S 1 15 REAR PANEL 124 2066 S 1 16 TIE ROD BODYWORK BLADE 120 1575 S 2 17 REAR LEFT UPRIGHT PANEL 124 2052 S 1 18 LEFT SIDE PANEL 124 2064 S 1 19 REAR C...

Страница 41: ...LID FROM SERIAL NUMBER 6041 FRONT SIDE SECT ON RIGHT RAD x RVK 25 30 INVERTER 118 1160 S 26 FRONT SIDE SECT ON RIGHT RAD x RVK 40 INVERTER 118 11765 S 1 27 ELECTRIC BOX SUPPORT BLADE 120 1565 S 1 28 M...

Страница 42: ......

Страница 43: ...TER x RVK 25 30 029 19567 S 14 ELECTRIC BOX AIRM S1 INVERTER x RVK 25 30 40 029 195672 S 1 ELECTRONIC CARD TELMAT 269 410 S 15 ELECTRONIC CARD AIRMASTER S1 269 4005 S 1 16 EMERGENCY SWITCH 154 066 S 1...

Страница 44: ...T RADIUS ELBOW M F 1 111 055 S 1 39 REDUCTION ELEMENT 1 1 4 M 1 F 190 070 S 2 40 ADAPTER FITTING AND STRAIGHT M F GIR 1 148 006 S 1 41 AUTOMATIC CONDENSATION DISCHARGER 237 200 S 1 42 CONDENSATION SEP...

Страница 45: ......

Страница 46: ...WASHER D10 1x15x1 5 015 005 S _ 13 REDUCTION ELEMENT 1 4 M A 12x1 5 F 190 013 S 1 14 90 RAPID FITTING 1 4 FOR PIPE D8 148 573 5 S 4 15 4 WAY BLOCK UNIT 1 4 053 295 S 1 16 BLOCK SUPPORT 010 1974 S 1 17...

Страница 47: ......

Страница 48: ...PULLEY SPACER 009 2165 S 1 8 MOTOR PULLEY WASHER 015 061 S 1 9 HORIZONTAL TANK 037 081 S 1 10 COMPRESSOR PULLEY WASHER 015 068 S 1 11 COMPRESSOR PULLEY SPACER 009 142 S 1 RVK 25 8bar COMPRESSOR PULLEY...

Страница 49: ......

Страница 50: ...LVE 1 2 12 bar 033 051 S SAFETY VALVE 1 2 14 bar 033 053 S 8 SAFETY VALVE 1 2 17 bar 033 0575 S 1 9 OIL LEVEL ROD CAP 106 0101 S 1 10 OR SEAL 023 026 5 S 1 11 REGULATOR BASE 034 001 S 1 12 SEGMENT 199...

Страница 51: ......

Страница 52: ...EMENT 2 M 1 F ONLY RVK25 40 TANK 190 098 S 1 5 WASHER 1 015 017 S 3 6 HEXAGONAL HEAD IRON CAP 1 106 135 S 2 SAFETY VALVE 1 2 12 bar 033 051 S SAFETY VALVE 1 2 14 bar 033 053 S 7 SAFETY VALVE 1 2 15 ba...

Страница 53: ......

Страница 54: ...X X 3 064 03210 S FROM BY PASS TO RADIATOR ENTR X X X X X X X X 4 064 03220 S FROM RADIATOR EXIT TO BY PASS X X X X X X X X 5 064 03230 S FROM BY PASS TO SCREW INJECTION X X X X X X X X 6 064 01012 S...

Отзывы: