Controller Functionality
AYC-W6500 Installation Manual
Page 50
en
Auxiliary Mode 7
Auxiliary Input behavior
When the auxiliary input is held op
for more than a set duration, the
auxiliary output opens.
Auxiliary Output behavior
When triggered, the auxiliary output
opens after a set duration.
ed)
(Auxiliary output is normally clos
Auxiliary Output trigger
The auxiliary output is triggered by
the auxiliary input.
Settings:
the auxiliary
Time in seconds before
output opens (01-99).
Example Use:
ry input and output, detect if the door has been left open
or was opened with a valid code bur remains open beyond a set
Using the auxilia
for too long.
If the do
duration, the auxiliary output informs an alarm system or sounds a siren.
The auxiliary input is connected to the door sensor output.
The auxiliary output is connected to the alarm system.