Controller Functionality
•
The unit sounds three short beeps to indicate the fingerprint has
been successfully enrolled.
•
If the fingerprint is not successfully enrolled, the unit sounds a
single long beep. Repeat the process from the beginning.
To Enroll Fingerprints in Secure Mode:
1. Present an enrolled proximity card.
•
The Reader status LED flashes green
.
2. Enter the PIN code of the same user.
•
The Reader status LED turns green
.
•
The fingerprint reader LED flashes orange
.
3. Place the user’s finger on the sensor.
•
The unit sounds a short beep followed by an additional three
short beeps.
•
The fingerprint reader LED flashes red
.
4. Place the user’s finger on the sensor again.
•
The unit sounds a short beep.
•
The fingerprint reader LED turns off.
•
The unit sounds three short beeps to indicate that the
fingerprint has been successfully enrolled.
•
If the fingerprint was not successfully enrolled, the unit sounds a
single long beep. Repeat the process from the beginning.
AYC-W6500 Installation Manual
Page 34
5.4
5.5
n be
connected to another device or alarm system, as necessary.
Door Alarms
Door alarms can be generated by connecting the unit's auxiliary input
(LED_CTL) to a Door Position Switch.
Both Door-Forced and Door-Ajar conditions are supported, with a
configurable delay timer for each alarm type. Only one Door-alarm is
enabled at any one time.
Case and Back Tamper
If the case of the controller is opened or the controller is removed from the
wall, a tamper event is triggered and a coded tamper signal is sent to the
secure power supply controller, or other compatible device, which
activates the siren. In addition, another output is opened, which ca