Controller Functionality
2. Press
“6” to enter Menu 6.
AYC-W6500 Installation Manual
Page 41
3.
ns below:
Auxiliary Mode
Auxiliary Setting
6
Construct the using the instructio
•
Each of the Auxiliary Modes has a two digit setting that affects
how the Auxiliary Mode functions.
The second digit defines the Auxiliary function.
The third and fourth digits sometimes define delay times for door
monitor functions. Otherwise, they have no affect and can be set
to any number.
Auxiliary Option Menu
The following quick reference guide indicates the behavior of the auxiliary
input and output in each auxiliary mode.
Aux
Mode
Auxiliary Input
Behavior
Auxiliary Output
Trigger
Settings
0 Closes
Output
•
Auxiliary input
closes
•
Testcode2
entered
•
"Open Aux" user
enters card or
PIN code
Duration (secs)
output closed
(01-99).
("00" toggles output.)
1 Toggles
Controller
between Normal
and Secure modes.
•
Testcode2
entered
•
"Open Aux" user
enters card or
PIN code
Duration (secs)
output closed
(01-99).
("00" toggles output.)