![Rosslare AYC-W6500 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/rosslare/ayc-w6500/ayc-w6500_installation-and-operation-manual_1489269031.webp)
Reader Functionality
Note:
When choosing the 4-8 digit option, you can either enter zeros
before the code, or press pound at the end (for example if
code is 12345, enter either 00012345 or 12345#).
•
The Reader status LED flashes green
.
3. Enter your programming code.
•
If the programming code is valid, all
memory is erased. The unit sounds three beeps and the
controller returns to Normal Access Mode.
If the programming code is invalid the unit sounds a long beep and
the controller returns to Normal Access Mode without erasing the
memory of the controller.
Note:
The programming code cannot be deleted. For example,
0000 is invalid and will not delete the programming code.
Replacing a Lost Programming Code
In the event that the programming code is forgotten, the unit may be
reset after installation.
To Reset the Programming Code
1. Disconnect the unit from its power supply.
2. Activate the tamper sensor by removing the reader from the wall or
removing the reader's case.
3. Reconnect the reader to the power supply.
4. You have 10 seconds to enter Programming Mode using the factory
default programming code 1234
.
AYC-W6500 Installation Manual
Page 30
Содержание AYC-W6500
Страница 1: ...AYC W6500 Integrated Reader and Controller Installation Operating Guide June 2008 ...
Страница 2: ......
Страница 13: ...Installation Figure 6 PC Connection Using RS 232 Cable AYC W6500 Installation Manual Page 12 ...
Страница 65: ......
Страница 66: ...0706 0960098 02 www rosslaresecurity com ...