Refer to
on page 17 for more
information on using the panel rows.
Fade to Black
This module is used to cut or dissolve the output
of the switcher to internally generated black.
The display on this module indicates the current
rate for the fade to black dissolve by default.
When the switcher is at black, the on-air source
buttons and tallies flash.
Global Memory Module
This module is used to store and recall
memories, set attributes, and set rates for any
or all MEs on the switcher. Using the keypad
you can also load stills into the Global-Store or
ME-Store, load clips on a server, or run a custom
control.
7
8
9
4
5
6
1
2
3
RUN CC
+/-
0
.
BANK
CLEAR
ENTER
ME
2
ALL
ME
1
RECALL
CLIP/CC
ALL
ME
4
ME
3
ME
1
ME
2
ME
4
ME
3
FADE
RATE
+4
ME
RATE
EFF
RATE
KEY
RATE
UNDO
ATTRIB
KE YS
ON LY
EFF
DISS
GLOBAL MEMORY
RECALL
STORE
Table 2: Memory Module Button Functions
Function
Button
Allows you to select all the MEs for a
store or recall.
ALL
Allows you to select individual MEs for
a store or recall. Press and hold an ME
button and then select the other MEs
you want to include. Use the +4 button
to access MEs 5 through 8.
ME X
Allows you to undo the last memory
recall. The UNDO button lights up
after each memory recall, indicating
that the action can be undone. If you
perform 10 or more button presses
after the memory recall, the UNDO
button goes out, and the memory can
no longer be recalled.
UNDO
Allows you to either recall a clip on the
selected device using a Clip ID or Clip
Number by entering it using the
keypad on the Global Memory module,
or run a custom control by entering
the bank and custom control number.
The functionality of the Recall Clip/CC
button is set using the CC Global Recall
personality option.
RECALL CLIP/CC
Function
Button
Allows you to view the memory
attributes menu, or override the
attributes stored with the memory
with the default attribute settings. To
override attributes, press and hold the
ATTRIB button while recalling the
memory.
ATTRIB
Allows you to recall a memory on a
panel row that does not include the
program and preset bus selections.
Only the keyer selections are recalled.
KEYS ONLY
Allows you to have the keys from one
memory slew into the keys from the
one you are recalling.
EFF DISS
Allows you to run a custom control
that you have recalled using the
RECALL CC button.
RUN CC +/-
Allows you to select the bank that you
want to store, or recall, a memory
register to.
BANK
Allows you to clear your current entry.
For example, if you are entering a
memory register to recall, but then
decide not to recall the memory, you
can press the CLEAR button to return
the Global Memory module to the
previous state.
CLEAR
Allows you to select an ME above ME
4. When the +4 button is held, the ME
1 through ME 4 buttons become ME 5
through ME 8 buttons respectively. For
example, if you want to select ME 6,
press and hold the +4 button on, and
press ME 2. Both the ME 2 and +4
buttons will remain lit.
+4
Allows you to set a new fade to black
rate.
FADE RATE
Allows you to set a new effects dissolve
rate for the ME.
EFF RATE
Allows you to set a new background
transition rate for the ME.
ME RATE
Allows you to set a new keyers
transition rate for the ME.
KEY RATE
Keyers Module
The keyers module is used to assign key types,
set up key modifiers, and perform independent
key transitions.