9-5
Rosemount Tank Radar Rex
Chapter 9 Technical Data
Service Manual
308012En, Ed.2
May 2013
9.5
RTG 3960
Instrument accuracy
RTG 3900 ± 0.5 mm ± (5/256 in.)
RTG 3900 L ± 3 mm ± (1/8 in.).
Operating temperature at
ball valve
-55 °C to 90 °C (-67 °F to 194 °F)
Operating temperature in
tank
-170 °C to 90 °C (-274 °F to 194 °F)
Ambient temperature
-40 °C to +70 °C
(-40 °F to +158 °F)
Measuring range
0.5 m to 60 m (1.6 ft to 200 ft) from cone end.
Maximum pressure
Up to 25 bar (365 psig)
Pressure sensor (option)
Druck PTX 621
Material exposed to tank
atmosphere
Antenna: Acid proof steel type EN 1.4436 (AISI
316)
Sealing: Quartz
Total weight
6 in. 150 lbs-appr. 38 kg (84 lbs)
6 in. 300 lbs-appr. 48 kg (106 lbs)
Still-pipe dimensions
4 in. Sch 10 or 100 mm inner diameter.
Содержание TankRadar Rex DAU 2100
Страница 2: ......
Страница 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Страница 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Страница 12: ...Rosemount Tank Radar Rex Chapter 1 System Description 1 4 Service Manual 308012En Ed 2 May 2013 ...
Страница 44: ...Rosemount Tank Radar Rex Chapter 3 Device Description 3 30 Service Manual 308012En Ed 2 May 2013 ...
Страница 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Страница 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Страница 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Страница 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Страница 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Страница 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Страница 153: ......