4-55
Rosemount Tank Radar Rex
Chapter 4 Service
Service Manual
308012En, Ed.2
May 2013
3
Set the
database register
that specifies the temperature range to the
value that corresponds to the jumper settings.
In TankMaster WinSetup:
In the
DAU configuration
window
click the
Configure
button next to the
Number of Temperature Sensors
field.
Note!
See spare parts list for part number of reference resistors.
Table 4-3: Temperature Range
Temperature
Range
Pt 100 / Cu 90
X1
X2
X3
Reference
Resistor (
)
-50 - +125 °C
OPEN
OPEN
CLOSED
138.50
-50 - +300 °C
CLOSED
CLOSED
CLOSED
175.84
-200 - +150 °C
CLOSED
CLOSED
OPEN
24.90
Sensor range
Содержание TankRadar Rex DAU 2100
Страница 2: ......
Страница 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Страница 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Страница 12: ...Rosemount Tank Radar Rex Chapter 1 System Description 1 4 Service Manual 308012En Ed 2 May 2013 ...
Страница 44: ...Rosemount Tank Radar Rex Chapter 3 Device Description 3 30 Service Manual 308012En Ed 2 May 2013 ...
Страница 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Страница 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Страница 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Страница 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Страница 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Страница 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Страница 153: ......