Reference Manual
00809-0100-4727, Rev EA
October 2010
Rosemount 8700 Series
www.rosemount.com
Appendix A
Reference Data
Rosemount 8700 Series Product Specifications Overview page A-1
E-Series Performance Specifications . . . . . . . . . . . . . . . . page A-5
High Signal System Performance Specifications . . . . . . page A-7
Rosemount Flanged Sensor Specifications . . . . . . . . . . . page A-9
Rosemount 8711 Wafer Sensor Specifications . . . . . . . . page A-13
Rosemount 8721 Sanitary Sensor Specifications . . . . . . page A-16
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-20
ROSEMOUNT 8700 SERIES PRODUCT SPECIFICATIONS OVERVIEW
Listed below are tables that outline some of the basic performance, physical, and functional specifications of the
Rosemount 8700 Series Magnetic Flowmeter products.
Table A-1. Rosemount 8700 Series Sensor Specifications
Model
Style
Base
Accuracy
(1)
(1) For complete accuracy specifications, please refer to the sensor detailed specifications.
Line Sizes
Coil Drive
Power
Design
Features
Page for
Detailed
Specifications
Page for
Ordering
Information
8705
Flanged
0.25%
Standard
0.15% High
Accuracy
Option
0.5 to 36 in.
(15 to 900 mm)
Pulsed DC
Standard
Process
Design
8707
High-Signal
(Flanged)
0.5%
Standard
0.25% High
Accuracy
Option
3 to 36 in.
(15 to 900 mm)
High-Signal
Pulsed DC
Superior
signal
stability for
Noisy
Applications
8711
Wafer
0.25%
Standard
0.15% High
Accuracy
Option
0.15 to 8 in.
(4 to 200 mm)
Pulsed DC
Compact,
Light
Weight
8721
Hygienic
0.5%
Standard
0.25% High
Accuracy
Option
0.5 to 4 in.
(15 to 100 mm)
Pulsed DC
3-A and
EHEDG
CIP/SIP
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
+86-755-8660-6182