Reference Manual
00809-0100-4663, Rev BA
January 2010
Rosemount 8732
www.rosemount.com
Appendix G
Transducer Block
Parameters and Descriptions . . . . . . . . . . . . . . . . . . . . . . page G-2
Flow-Specific Block Configuration Values . . . . . . . . . . . . page G-3
Transducer Block Errors . . . . . . . . . . . . . . . . . . . . . . . . . . page G-4
Transducer Block Diagnostics . . . . . . . . . . . . . . . . . . . . . page G-5
Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page G-5
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page G-6
This appendix contains information on the transducer block for the
Rosemount 8732 Magnetic Flowmeter Transmitter (see Figure G-1).
Descriptions of all transducer block parameters, errors, and diagnostics are
listed. Also, the modes, alarm detection, status handling, application
information, and troubleshooting are discussed.
Figure G-1. Transducer
Block Diagram
Definition
The transducer block contains the actual flow measurement data. This data
includes information about sensor type, engineering units, digital filter
settings, damping, and diagnostics. Only a single channel is defined in the
Rosemount 8732. Channel 1 provides flow measurements to the analog input
(AI) block.
Diagnostics
A/D Signal
Conversion
Flow
Da
m
p
in
g
Un
it
s/ R
a
ng
ing
Diagnostics
A/D Signal
Conversion
Flow
Da
m
p
in
g
Un
it
s/ R
a
ng
ing
TB
Содержание 8732 Series
Страница 2: ......
Страница 4: ......
Страница 10: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 TOC 6 ...
Страница 26: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 2 14 ...
Страница 38: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 3 12 ...
Страница 92: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 A 8 ...
Страница 107: ...Reference Manual 00809 0100 4663 Rev BA January 2010 B 15 Rosemount 8732 Figure B 1 ATEX Installation 1 of 6 ...
Страница 108: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 B 16 Figure B 2 ATEX Installation 2 of 6 ...
Страница 109: ...Reference Manual 00809 0100 4663 Rev BA January 2010 B 17 Rosemount 8732 Figure B 3 ATEX Installation 3 of 6 ...
Страница 110: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 B 18 Figure B 4 ATEX Installation 4 of 6 ...
Страница 111: ...Reference Manual 00809 0100 4663 Rev BA January 2010 B 19 Rosemount 8732 Figure B 5 ATEX Installation 5 of 6 ...
Страница 112: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 B 20 Figure B 6 ATEX Installation 6 of 6 ...
Страница 113: ...Reference Manual 00809 0100 4663 Rev BA January 2010 B 21 Rosemount 8732 Figure B 7 FM Certified I S Output 1 of 4 ...
Страница 114: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 B 22 Figure B 8 FM Certified I S Output 2 of 4 ...
Страница 115: ...Reference Manual 00809 0100 4663 Rev BA January 2010 B 23 Rosemount 8732 Figure B 9 FM Certified I S Output 3 of 4 ...
Страница 116: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 B 24 Figure B 10 FM Certified I S Output 4 of 4 ...
Страница 117: ...Reference Manual 00809 0100 4663 Rev BA January 2010 B 25 Rosemount 8732 Figure B 11 CSA Certified I S Output 1 of 2 ...
Страница 118: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 B 26 Figure B 12 CSA Certified I S Output 2 of 2 ...
Страница 119: ...Reference Manual 00809 0100 4663 Rev BA January 2010 B 27 Rosemount 8732 Figure B 13 CSA Installation ...
Страница 120: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 B 28 Figure B 14 Factory Mutual Hazardous Locations ...
Страница 186: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 H 8 ...
Страница 189: ......