![Rosemount 1199 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/rosemount/1199/1199_reference-manual_1487371037.webp)
Reference Manual
00809-0100-4002, Rev BB
November 2012
3-17
Rosemount 1199
Clamp and Gasket
The clamp and gasket are furnished by the user. Maximum pressure rating of
the system is dependent upon the clamp pressure rating.
High Process
Connection
MWP at 70F (psi)
MWP at 250F (psi)
1 1/2 in.
1500
1200
2 in.
1000
800
2 1/2 in.
1000
800
3 in.
1000
800
4 in.
1000
800