Device functions
Seite 30
UPT-6010
Version 2
24/25
Heatup timeout (10 ms steps)
0 s
0…999
(0…9.99 s)
26
Temperature OK bit
Active when Tact=Tset
Off (0),
active when Tact=Tset (1),
active when Tact=Tset
with latch (2)
27
Hold mode
Off
Off (0), on (1), 2 s (2)
28
Calibration temperature, channel 1
20 °C
-1, 0…40 °C
29
Correction factor, channel 1
100%
25…200
(25…200%)
30/31
Temperature coefficient, channel 1
1700 ppm/K
400…4000 ppm/K
32
Calibration temperature, channel 2
20 °C
-1, 0…40 °C
33
Correction factor, channel 2
100%
25…200
(25…200%)
34/35
Temperature coefficient, channel 2
1700 ppm/K
400…4000 ppm/K
36
Calibration temperature, channel 3
20 °C
-1, 0…40 °C
37
Correction factor, channel 3
100%
25…200
(25…200%)
38/39
Temperature coefficient, channel 3
1700 ppm/K
400…4000 ppm/K
40
Calibration temperature, channel 4
20 °C
-1, 0…40 °C
41
Correction factor, channel 4
100%
25…200
(25…200%)
42/43
Temperature coefficient, channel 4
1700 ppm/K
400…4000 ppm/K
44
Calibration temperature, channel 5
20 °C
-1, 0…40 °C
45
Correction factor, channel 5
100%
25…200
(25…200%)
46/47
Temperature coefficient, channel 5
1700 ppm/K
400…4000 ppm/K
48
Calibration temperature, channel 6
20 °C
-1, 0…40 °C
49
Correction factor, channel 6
100%
25…200
(25…200%)
50/51
Temperature coefficient, channel 6
1700 ppm/K
400…4000 ppm/K
52
Calibration temperature, channel 7
20 °C
-1, 0…40 °C
53
Correction factor, channel 7
100%
25…200
(25…200%)
54/55
Temperature coefficient, channel 7
1700 ppm/K
400…4000 ppm/K
1. The default value is stored in the device master file (GSDML) and transferred from the PROFINET con-
troller to the UPT-6010 when the system is started up.
Index
Function
Default value
1
Value range