Device functions
Version 2
UPT-6010
Seite 29
8.6.13 Error codes
If a fault is signalled (AL bit = 1), you can determine the exact cause with the help of the error code. The error code
is contained in the third word at bit positions 0…9 (
section 8.19 "Error messages" on page 46).
In addition to the error codes, the PROFINET diagnosis function also sends error messages to the PROFINET
controller. The error messages corresponding to each error code are already stored in the device master file
(GSDML), so that they automatically appear in plain text on the PROFINET controller when a device diagnosis for
the UPT-6010 is requested there. The error messages are stored in the GSDML file in English and German. You
can select the language in the configuration tool.
8.7
Parameter data
The parameter data contains values for selecting the heating element alloy, the temperature range, the high and
low tolerance limits for temperature monitoring, the calibration temperature, and the optional heating time limit. It
is transferred from the PROFINET controller to the UPT-6010 each time the system is started up. The parameters
can also be queried by the PROFINET controller or transmitted by it to the UPT-6011 controller at any time using
asynchronous read / write services. They are not stored in the UPT-6010. The parameter data can be addressed
at slot 1, subslot 1, starting at index 4. It has the following structure:
Index
Function
Default value
1
Value range
4
Temperature range / alloy
10
0, 4, 9, 10, 11 (
5
Low temperature OK threshold
10 K
3…99 K
6
High temperature OK threshold
10 K
3…99 K
7
Calibration temperature
20 °C
-1, 0…40 °C
8/9
Heating time limit (10 ms steps)
500
0…999
(0…9.99 s)
10
External module / channel errors
On
Off (0), on (1)
11
Measuring impulse duration
17
17…30
(1.7…3.0 ms)
12
Data format
Little Endian (Intel)
Little Endian (Intel) (0),
Big Endian (Motorola) (1)
13
Correction factor
100%
25…200
(25…200%)
14/15
Maximum start temperature
100 °C
20…500
(20…500 °C)
16/17
Temperature coefficient
1700 ppm/K
400…4000 ppm/K
18
Temperature range
300 °C
200 °C (0), 300 °C (1),
400 °C (2), 500 °C (3)
19/20
Maximum temperature
300 °C
200…500 °C
21
Temperature diagnosis
Off
Off (0), on (1)
22/23
Temperature diagnosis delay (10 ms
steps)
0 s
0…999
(0…9.99 s)