Startup and operation
Version 2
UPT-6010
Seite 17
7.2.2
Configuration of the rotary coding switch for the temperature range and alloy
The setting of the rotary coding switch for the temperature range and alloy can be overwritten with
the parameter data (
section 8.7 "Parameter data" on page 29).
If the switch is set to "9", more temperature ranges and alloys can be selected in the ROPEX visualization software
(
section 8.12 "USB interface for visualization software ROPEXvisual
7.2.3
Configuration of the rotary coding switches for device names
These coding switches can be used to specify the names of the UPT-6010 devices in the PROFINET network. A
new setting does not take effect until the next time the controller is switched on.
The preset device name "UPT-6010" is configured as follows, depending on the settings of the rotary coding
switches:
By assigning device names using rotary coding switches, you can replace a device in an existing machine without
a programming tool. Simply configure the replacement device with the same switch settings.
If the UPT-6010 was named using a suitable PROFINET tool (e.g. Siemens STEP7), the preset device name can
be erased by means of the rotary coding switches. To do this, make sure the controller is de-energized, then set
the switches to 0xFF and switch the controller on again. It is sufficient to supply the controller with 24 VDC. No
connection is required to the PROFINET network. After the device name has been successfully erased, the red
DATA EXCHANGE LED blinks at approx. 4 Hz. The power supply to the controller must then be momentarily inter-
rupted in order for the new switch settings to take effect.
Rotary coding switch
Device name
00
Last name assigned is static
01…FE
UPT-6010-
01
…UPT-6010-
FE
FF
Last device name assigned and I&M data erased
0
5
1
2
3
4
6
7
8
9
AUX
CONF
IG
URA
TIO
N
ALARM
OU
TP
UT
ENER
GIZ
ED
(
)
AT
ALARM
-
DEE
NE
RG
IZ
ED
SWIT
CH
PO
S
.
4
0
9
TE
MP
RANGE
.
500°
C
300°
C
PC
CON
FIG
UR
AT
IO
N
1700
pp
m/K
1700
pp
m/K
(
)
CIR
US
(
)
CIR
US
0
5
1 2
3
4
6
7
8
9
Switch
position
0
4
300°C
500°C
1700ppm/K
1700ppm/K
(CIRUS)
(CIRUS)
Temp.
range
Temp.
coefficient
Heating element
alloy
0 = Factory settings
9
PC-CONFIGURATION
TEM
P . C
OE
FFIC
IEN
T
!!
0
0
F
F
E
E
D
D
C
C
B
B
A
A
9
9
8
8
7
7
6
6
5
5
44 3
3
2
2
1
1
Station name selectable.
00 = Factory settings
0...F
0...F
(Controller_type: RES-5010 / UPT-6010)
Device name selectable
by PROFINET config tool
Device name preset to
“Controller_type -XX”
Erase name
00
01...FE
FF
0
0
F
F
E
E
D
D
C
C
B
B
A
A
9
9
8
8
7
7
6
6
5
5
44 3
3
2
2
1
1