Device functions
Version 2
UPT-6010
Seite 31
The date, time, operating hours counter, and counters for the individual calibration channels can be read out at
slot 1, subslot 2. Apart from the operating hours counter (index 4…7) and the non-clearable total cycle counter
(index 8…11), these counters can also be reset by means of a write access.
A plausibility check which takes account of leap years is performed after writing the date or time. If the transferred
values do not contain any valid date or time information, the UPT-6010 responds with an access error: 0xb7
"Invalid Range". To prevent inconsistencies, the individual date or time values should be changed together with a
single write access, in other words index 0…3 and 4…7.
The start temperature (
section 8.6.12 "Start temperature" on page 28) and the internal device temperature are
available at slot 1, subslot 3. They are read-only values which cannot be written,
The channel-specific deviations from the calibration data are available at slot 1, subslot 4 (
AUTOCAL (MA)" on page 26). They are read-only values which cannot be changed. The absolute calibration
Index
Function
Default value
Value range
0
Date: Day
1…31
1
Date: Month
1…12
2/3
Date: Year
2000…2099
4
Time: Milliseconds (not used)
1
1. Milliseconds are not supported by the internal real-time clock. Read accesses always return 0. A value
in the range 0…99 must be transferred during write accesses or the UPT-6010 will respond with an
access error: 0xb7 "Invalid Range".
0
0…99
5
Time: Seconds
0…59
6
Time: Minutes
0…59
7
Time: Hours
0…23
8…11
Operating hours (in 0.1h)
0.0 h
0…99999999.9 h
12…15
Non-clearable total cycle counter
0
0…999999999
16…19
Clearable total cycle counter
0
0…999999999
20…23
Cycle counter, channel 0
0
0…999999999
24…27
Cycle counter, channel 1
0
0…999999999
28…31
Cycle counter, channel 2
0
0…999999999
32…35
Cycle counter, channel 3
0
0…999999999
36…39
Cycle counter, channel 4
0
0…999999999
40…43
Cycle counter, channel 5
0
0…999999999
44…47
Cycle counter, channel 6
0
0…999999999
48…51
Cycle counter, channel 7
0
0…999999999
Index
Function
Default value
Value range
0/1
Start temperature
-99 °C
-99…500 °C
2/3
Device temperature
-60…190 °C