Gas connection
The appliances operate on the following gases: Butane G30, Propane G31, natural gases
G20/G25 and at all pressures encountered on main gas. Connection is with a G 1/2 thread.
The appliances are supplied from the factory with a Butane/Propane.
Connect the appliance to the gas supply pipe, interposing a stop valve, which enables the
appliance to be isolated from the rest of the installation. Check that the settings correspond to
the type and pressure of the gas distributed in the installation.
Check the supply pressure with all the burners alight using a gas manometer. This should be
the same as indicated on the identification plate.
General conditions for installation
The installation and the maintenance of the appliance must be carried out in accordance with
the current regulations and rulebook, in particular:
Regulations for the prevention of fire and panic in establishments when the public is
admitted.
General provisions:
1°
For all appliances:
Article GZ
Installations using combustible gases and liquid hydrocarbons
2°
Next, depending on the use:
Article CH
Heating, ventilation, refrigeration, air conditioning and the
production of steam from hot water in sanitary installations.
Article GC
Installation of appliances to be used for catering. Specific
provisions for each type of establishment to which the public is admitted (hospitals, shops,
etc…).
Changing the gas
Important:
Do not rebore the injectors.
The injectors are removed and replaced using a 8 ring spanner.
To change the gas from G30/G31 to G20/G25 you must adjust the low position. For this,
unscrew the By Pass screw of 3 rounds. In the other case, screw the By Pass at the
maximum and take off the air collar.
Country of
Destination
Category
Gas
Pressures
Injecteur
RBG80-120-
200
Injector
RBG 30
Air collar
France
II2E+3+
II2E+3B/P
II2E+3P
G20/G25
G30/G31
G20/G25
G30
G31
G20/G25
G31
20/25
28-30/37
20/25
50
50
20/25
50
175
120
175
120
120
175
120
150
100
150
85
90
150
90
No
No
No
No
No
No
No
Germany
II2ELL3B/P
G20
G25
G30
G31
20
20
50
50
175
175
120
120
150
160
85
90
No
No
No
No
Austria
II2H3B/P
G20
G30
G31
20
50
50
120
120
120
150
85
90
No
No
No
Belgium
I2E+
I3+
G20/G25
G30/G31
20/25
28-30/37
175
120
150
100
No
No
Sweden/Denmark/
Finland
II2H3B/P
G20
G30/G31
20
28-30/30
175
120
150
100
No
No
Spain
II2H3+
II2H3P
G20
G30/G31
G20
G31
20
28-30/37
20
50
175
120
175
120
150
100
150
90
No
No
No
No
Luxembourg
II2E3B/P
II2E3+
G20
G30
G31
G20
G30/G31
20
50
50
20
28-30/37
175
120
120
175
120
150
85
90
150
100
No
No
No
No
No
Netherlands
II2L3B/P
II2L3P
G25
G30/G31
G25
G31
25
28-30/30
25
50
175
120
175
120
150
100
150
90
No
No
No
No
Norway
I3B/P
G30/G31
28-30/30
120
100
No
Iceland/Greece/United
kingdom/Italy/Portugal
II2H3+
G20
G30/G31
20
28-30/37
175
120
150
100
No
No
Electrical connection
The electric motor must be connected to the single-phase 220/230 V mains supply
Maker’s name
The identification plate is located on the back of the appliance
If the gas is changed, change the setting label.