![Roland TrueVIS SG-300 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/roland/truevis-sg-300/truevis-sg-300_user-manual_1481445040.webp)
B asic P rinting Method
2
B
asic
O
p
eration
38
C
V iew the p rinted test p attern, and then determine the correction values f rom " B I-DIR
NO .1 H 1 " and " B I-DIR NO .1 H 2 ."
The test pattern is made of groups of two lines. Select the value that gives the least misalignment
between the two lines. In the case of the following figure, select "+5" for H1
,
"+4" for H2. When you
cannot choose between two sequential numbers, select a value that is between them (you can set
correction values in units of "0.5").
D
Set the correction values f rom " H 1 " to " H 2 ."
1
P ress [ ] or [ ] to select the correction value.
H1 H2
0 0
2
hen ou ha e nished setting the correction alues, ress
The screen shown below appears again.
E
P ress [ ] to disp lay the screen shown below.
F
Set the correction values f rom " B I-DIR NO .2 H 1 " to " B I-DIR NO .2 H 2 " in the same
manner as step
D
.