Correction Functions
4
Advanced
Functions
123
C
V iew the p rinted test p attern, and then determine the correction value.
Select the value to make the gap and overlap between the upper/lower squares smallest. In the case
of the following figure, select "-0.40." When you cannot choose between two sequential numbers,
specify a value that is between them.
= C u r r e n t co
r r e ct i o n va
l u e
G a p p r e se
n t
O ve
r l a p
D
P ress [ ] or [ ] to select the correction value.
SETTING
0.00% -0.40%
E
ress
to con rm our entr
F
Rep eat step
1
to check whether the correction was successf ul.
Check that the gap and overlap are the smallest for the figure indicated by "
" (that is, the current
correction value). If the gap and overlap are smaller for another figure, set the correction value again.
G
W
hen y ou have successf ully p erf ormed the correction, p ress [ MENU] to go back to
the original screen.
Descrip tion
The movement distance of the media changes subtly depending on the media's thickness and the temperature
of the dryer. When the movement distance becomes discrepant, horizontal stripes are more likely to occur
during printing. We recommend that you make corrections to match the media you are using and the set
temperature of the dryer. Repeat the process of printing a test pattern and entering a correction value several
times to find the optimal value.
Depending on the software RIP you are using, you can also make this setting in the software RIP (by, for exam-
ple, choosing the media type). When you have made the setting in the software RIP, the software RIP's setting
is used and the printer's setting is ignored.