192
Settings Common to All Modes (System Function)
MTC Error Level
Determines how often the reception status is checked when MTC is
being received from an external device. Stop synchronization if a
problem becomes apparent with the check.
Value:
0–10 (the checking interval will be longer for larger values)
In strict terms, the lower the numerical value set, the more
accurate the check is. However, playback may be stopped overly
frequently if too rigorous a check is made, and this soon becomes
inconvenient. By raising the Error Level setting, then even if
problems with the reception of MTC do occur, synchronization
can then continue as long as such problems remain at a level that
does not cause undue problems.
Metronome
Metronome Mode
Specifies when you want the metronome to sound.
* If there is a check mark next to [7 (Click)] in the Tempo window, which
appears when you press [TEMPO], the metronome will always sound.
Value
OFF:
Will not sound.
PLAY ONLY:
Will sound only during playback.
REC ONLY:
Metronome will sound only for recording.
PLAY&REC:
Metronome will sound for playback and recording.
ALWAYS:
Metronome will always sound.
Metronome Level
You can adjust the volume of the metronome.
Value:
0–10
Metronome Sound
Selects the metronome sound.
Value
TYPE 1:
A conventional metronome sound will be heard. A bell will
sound on the first beat.
TYPE 2:
Clicks will sound.
TYPE 3:
Beeps will sound.
TYPE 4:
Cowbell will sound.
MIDI
Device ID (Device ID Number)
When you want to transmit or receive System Exclusive messages,
set this parameter to match the Device ID number of the other MIDI
device.
Value:
17–32
Performance Control Channel
Performance Ctrl Ch selects the MIDI receive channel used during
switching of performances when MIDI messages (Program Change/
Bank Select) are sent from an external MIDI device. Set this to “OFF”
if performances are not to be switched from an external MIDI device.
Value:
1–16, OFF
If only a program change is received, and if the Performance Ctrl
Ch parameter setting coincides with the MIDI receive channel of
a part, priority will be given to switching the performance.
Kbd Patch Rx/Tx Ch
(Keyboard Patch Receive/Transmit Channel)
Specifies the channel used to transmit and receive MIDI messages
for the Keyboard part in Patch mode.
Value:
1–16
Pad Patch Rx/Tx Ch
(Pad Patch Receive/Transmit Channel)
Specifies the channel used to transmit and receive MIDI messages
for the Pad part in Patch mode.
Value:
1–16
Transmit Program Change
(Transmit Program Change Switch)
Specifies whether Program Change messages will be transmitted
(ON) or not (OFF).
Value:
OFF, ON
Transmit Bank Select (Transmit Bank Select Switch)
Specifies whether Bank Select messages will be transmitted (ON) or
not (OFF).
Value:
OFF, ON
Transmit Active Sensing
(Transmit Active Sensing Switch)
Specifies whether Active Sensing messages will be transmitted (ON)
or not (OFF).
Value:
OFF, ON
Transmit Edit Data (Transmit Edit Data Switch)
Specify whether changes you make in the settings of a patch,
performance will be transmitted as system exclusive messages (ON),
or will not be transmitted (OFF).
Value:
OFF, ON
Soft Through (Soft Through Switch)
Thru function re-transmits all messages received at the MIDI IN
connector to the MIDI OUT connector without modifying them in
any way. Normally you’ll leave this “OFF,” but when using an
external sequencer, you should set it “ON.”
Value:
OFF, ON
Reference_e.book 192 ページ 2003年7月14日 月曜日 午後3時25分