28
• Selecting the instruction set
COMMAND MODE
Display readout
Factory default setting
AUTO
Available settings
1 (mode 1) / 2 (mode 2) / AUTO
Explanation
This selection enables the type of instructions that are understood by the unit.
You can set the unit to accept either CAMM-GL III mode 1 instructions (“1”) or
mode 2 instructions (“2”).
When set to “AUTO,” the PNC-1850/1200 automatically detects the type of
instructions first received after turning on the power, and sets itself to accept those
instructions.
To change the type of instructions, first change the setting, then switch the power
to the unit off and back on again.
Procedure
At the top menu, press the
MENU
key once. Press
or
to move the
blinking cursor to “SUBMENU” on the right side of the lower line of the display,
press
ENTER
, then press
MENU
twice. Use
or
to move the blinking
cursor to “COMMAND” on the left side of the upper line of the display, and press
ENTER
again. Change the value with
or
and press
ENTER
to save the
setting.
COMMAND MODE
1 2 <AUTO>
Stop bit
• Setting the protocol for a serial connection
* The screen shown here appears when “SERI” (Serial) or “AUTO” is selected for “INTERFACE.”
STOP BIT
Display readout
Factory default setting
1
Available settings
1 / 2
Explanation
This marker tells the system when a character data set end.
Procedure
At the screen following selection of either “SERIAL” or “AUTO” for “INTER-
FACE,” use
or
to move the blinking cursor to “STOP” on the left side of
the lower line of the display, then press
ENTER
.
Use
or
to change the value, and press
ENTER
again to save the setting.
STOP BIT
<1> 2
• Selecting the connection interface
INTERFACE
Display readout
Factory default setting
AUTO
Available settings
PARA (Parallel) / SERI (Serial)
/ AUTO
Explanation
This selects the interface for connecting a computer to the PNC-1850/1200.
Set this to “PARALLEL” for a parallel connection or to “SERIAL” for a serial
connection.
When set to “AUTO,” the PNC-1850/1200 automatically detects whether a
parallel or serial type interface is used when data is first received after turning on
the power, and sets itself accordingly. To change the type of interface, first
switch off the power to the unit, change the cable connection, then turn the unit
back on again. See “1-4-4 Selecting the Interface” on page 14 for details.
Procedure
At the top menu, press the
MENU
key once. Press
or
to move the
blinking cursor to “SUBMENU” on the right side of the lower line of the display,
press
ENTER
, then press
MENU
twice.
Use
or
to move the blinking cursor to “I/O” on the right side of the upper
line of the display, and press
ENTER
again. Change the value with
or
and
press
ENTER
to save the setting.
INTERFACE
PARA SERI<AUTO>