7-2 Responding to an Error Message
feed do not result in an error.) After a short wait, this message
disappears. Close the cover, then try the operation again. (The
safety cover is an optional item.)
Close spindle cover
(Not displayed in VPanel.)
An operation that makes the machine perform a task involving
movement was attempted while the spindle cover was open.
After a short wait, this message disappears. Close the cover,
then try the operation again.
Command not recognized. Paused...
An RML-1 command that could not be interpreted was re-
ceived. Click [Clear Error], then click [Stop Cutting]. Canceling
the paused state and resuming cutting instead of quitting is
possible, but because unintended operation is highly likely,
doing so is not recommended.
Check whether the correct command mode is selected, and
check whether the program you're using is compatible with
the machine.
P. 45 "3-3 Selecting the Command Mode"
Command not recognized. Paused...
(Not displayed on the handy panel.)
An NC code that the machine does not support was received.
Click [Clear Error], then click [Stop Cutting]. Canceling the
paused state and resuming cutting instead of quitting is pos-
sible, but because unintended operation is highly likely, doing
so is not recommended.
Check whether the correct command mode is selected, and
check the program for errors.
P. 45 "3-3 Selecting the Command Mode"
Emergency stop
An emergency stop occurred because the spindle cover or
safety cover was opened or the handy panel became detached
while cutting was in progress. Cutting is interrupted and can-
not be resumed. Shut down the machine. (The safety cover
is an optional item.)
Incorrect parameter. Paused...
(Not displayed on the handy panel.)
Correct circular interpolation is not possible for a received NC
code because of a reason such as an extremely large param-
eter. Click [Clear Error], then click [Stop Cutting]. Canceling
the paused state and resuming cutting instead of quitting is
possible, but because unintended operation is highly likely,
doing so is not recommended.
Check whether the correct command mode is selected, and
check the program for errors.
P. 45 "3-3 Selecting the Command Mode"
Main cover open
An emergency stop occurred because the safety cover was
opened while feed was in progress. Closing the spindle cover
and clicking [Clear Error] returns the machine to the standby
state. Cutting is interrupted and cannot be resumed. Redo
the operation from the beginning. (The safety cover is an
optional item.)
No tool sensor connected
The cable for the tool sensor has come loose. Click [Clear Error],
then check the cable.
P. 73 "4-5 Using the Tool Sensor"
Parameter out of range. Paused...
(Not displayed on the handy panel.)
A received NC code contained a parameter that is outside the
permitted range. Click [Clear Error], then click [Stop Cutting].
Canceling the paused state and resuming cutting instead of
quitting is possible, but because unintended operation is
highly likely, doing so is not recommended.
Check whether the correct command mode is selected, and
check the program for errors.
P. 45 "3-3 Selecting the Command Mode"
Parameter undefined. Paused...
(Not displayed on the handy panel.)
The received NC codes contained an address with no value.
Click [Clear Error], then click [Stop Cutting]. Canceling the
paused state and resuming cutting instead of quitting is pos-
sible, but because unintended operation is highly likely, doing
so is not recommended.
Check whether the correct command mode is selected, and
check the program for errors.
P. 45 "3-3 Selecting the Command Mode"
S driver overheat
Cutting was stopped because the spindle-motor driver cir-
cuit overheated. Resuming is not possible. Shut down the
machine.
S driver overload
Cutting was stopped because the load on the spindle-motor
driver circuit exceeded its rated value. Resuming is not pos-
sible. Shut down the machine.
S motor overload. Paused...
Operation was paused because of large load on the spindle
motor. Click [Clear Error], cancel the paused state, then resume
cutting. Because the cutting may exceed the capacity of the
machine, revising the cutting parameters is recommended.
S overheat
Cutting was stopped because the spindle motor overheated.
Resuming is not possible. Shut down the machine.
S overload
Cutting was stopped because the load on the spindle motor
exceeded its rated value. Resuming is not possible. Shut down
the machine.
105
Chapter 7 What to Do If...
Содержание Aproll MDX-540
Страница 2: ......
Страница 23: ...21 Chapter 1 Introduction ...
Страница 31: ...29 Chapter 2 Emplacement and Installation ...
Страница 40: ...38 ...
Страница 41: ...39 Chapter 3 Basic Operation ...
Страница 58: ...56 ...
Страница 59: ...57 Chapter 4 Getting Ready for and Performing Cutting ...
Страница 79: ...77 Chapter 5 Handy Panel ...
Страница 94: ...92 ...
Страница 95: ...93 Chapter 6 Maintenance ...
Страница 103: ...101 Chapter 7 What to Do If ...
Страница 109: ...107 Chapter 8 Specifications ...
Страница 118: ......
Страница 119: ......
Страница 120: ...R9 180316 ...