Remote Control Commands
R&S
®
RTM3000
633
User Manual 1335.9090.02 ─ 08
Parameters:
<Source>
CH1 | CH2 | CH3 | CH4 | D0..D15
Logic channels D0..D15 are available if MSO option R&S
RTM-
B1 is installed.
*RST:
CH1
BUS<b>:CAN:TYPE
<SignalType>
Selects the CAN-High or CAN-Low line. CAN uses both lines for differential signal
transmission.
If you measure with a differential probe, connect the probe to both CAN-H and CAN-L
lines, and set the type CANH.
If you use a single-ended probe, connect the probe to either CAN_L or CAN_H, and
select the type accordingly.
Suffix:
<b>
.
1..4
Parameters:
<SignalType>
CANH | CANL
*RST:
CANH
BUS<b>:CAN:SAMPlepoint
<SamplePoint>
Sets the position of the sample point within the bit in percent of the nominal bit time.
See also:
Suffix:
<b>
.
1..4
Parameters:
<SamplePoint>
Range:
10 to 90
Increment: 1
*RST:
50
Default unit: %
BUS<b>:CAN:BITRate
<BitRate>
Sets the number of transmitted bits per second.
Suffix:
<b>
.
1..4
Parameters:
<BitRate>
Range:
100 to 5,04E06
Increment: Depends on the bit rate value
*RST:
50E03
Default unit: Bit/s