11 INSTALLATION
11.1
Preliminary checks
• Check that the material received is in good condition and suitable for the application.
• Check that the operating limits of the product are not exceeded.
• Check that the site chosen for installation meets the overall space requirements of the product and that there are no obstacles hindering open or close manoeuvres.
• Check the concrete base for the barrier installation. The base must be cast in accordance with proper working practices, perfectly level and clean.
11.2
Installing base plate
• The illustrations herein are indicative only. The space necessary for fastening the automation system and the accessories may vary depending on the overall dimensions
of the installation. The installer is responsible for determining the most suitable solution.
• Excavate a foundation pit measuring 1,5 m x 1 m x 0,5 m and fill with concrete reinforced with steel mesh.
• Fasten the 6 anchor ties to the plate (fig. 1). Note: the bottom nut must be tightened to the end of the thread on the screw so that the length Z is at least 40 mm.
• Sink the base plate with the anchors in the centre of the foundation pit, so that the surface is flush with the concrete and perfectly level. The corrugated cable conduits
must protrude by a few centimetres from the centre of the plate (fig. 2).
• Installation on existing surfaces. Place the base plate on the surface and trace the positions of the fastener points. Drill the surface and insert 6 adequately sized
expansion anchor bolts (purchased separately).
COD
. KT244
492
Z≥40
270
429
166
492
270
190
BIONIK8