background image

24V

1

2

v. 164-br

EN

USER / INSTALLER MANUAL

MC50BR

Содержание MC50BR

Страница 1: ...24V 1 2 v 164 br EN USER INSTALLER MANUAL MC50BR...

Страница 2: ...CELERATION SPEED P9 DISTANCE PROGRAMMING P1 SETTING THE DECELERATION TIME E3 FOLLOW ME P7 OPERATING LOGIC P4 PAUSE TIME E7 MANEUVERS COUNTER E0 PRESENT MAN P2 SETTING STRENGTH AND SENSITIVITY P8 FLASH...

Страница 3: ...to the automation components and or their accessories Keep remote controls away from children to prevent the automated system from being activated involuntarily The customer shall not under any circu...

Страница 4: ...riggering is visible on the display OP opening limit switch activated and CL opening limit switch activated It is mandatory the use of limit switches CN4 Safety circuits 01 This input allows connectio...

Страница 5: ...the display does not match the barrier s movement turn off the control board from the power supply e swap the 5 and 7 wires from CN1 and check if it is correct with 3 and 4 from CN2 ESSENTIAL STEPS F...

Страница 6: ...rity Band Disabled Security Band Activated 8k2 input NC input Band in closure Band in opening 00 01 00 8B OperatiNG logic Automatic mode function Step by step mode function Mode condominium function 0...

Страница 7: ...mming press simultaneously 01 Press MENU for 3 seconds min max 0s COURSE AUTOMATIC PROGRAMMING 04 PROGRAMMING P RAMP ADJUSTMENT 04 PROGRAMMING P 9s 02 P0 appears Press once 03 P1 appears Press MENU fo...

Страница 8: ...and reverse the direction Factory default 00 min max 1 9 07 P3 appears not available menu To program P4 continue in step 3 from P4 menu page 7B To exit the programming press simultaneously 04 PROGRAM...

Страница 9: ...you want change the it between 00 and 01 using 08 Appears the function set from factory If you want change the it between 00 and 01 using 11 Appears the function set from factory If you want change t...

Страница 10: ...on to 00 01 or 02 using OPERATING LOGIC 04 PROGRAMMING P 06 P9 appears To program P9 continue in step 3 from P9 menu page 10A To exit the programming press simultaneously FLASHING LIGHT 04 Appears the...

Страница 11: ...itter 03 P9 appears Press MENU for 3 seconds 05 Press MENU to save the defined function 01 Press MENU for 3 seconds 02 P0 appears Press 9 times 04 Appears the function currently set If you want change...

Страница 12: ...fined function 04 Appears the function currently set If you want change the function to 00 or 01 using SOFT START 05 PROGRAMMING E COURTESY LIGHT TIME 01 Press MENU for 10 seconds 02 E0 appears Press...

Страница 13: ...Follow me function P5 have to be set with HE 01 HC 00 see page 9A Factory default 01 05 PROGRAMMING E 04 Appears the function currently set If you want change the function to 00 or 01 using min max 4...

Страница 14: ...06 E8 appears To program E8 continue in step 3 from E8 menu page 13B To exit the programming press simultaneously 05 PROGRAMMING E 3 dozens 1 hundreds of thousands 2 thousands RESET RESTORE FACTORY V...

Страница 15: ...10A 03 E9 appears Press MENU for 3 seconds 01 Press MENU for 10 seconds RGB OUTPUT 05 Press MENU for 3 seconds to save the defined function 06 E1 appears To exit the programming press simultaneously 0...

Страница 16: ...etween the capacitator and the automatism wires is not important as long as it is connected one with the brown wire and the other with the black wire The common wire must always be connected to the po...

Страница 17: ...ge 15A 3 If the motor works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motor doesn t work remove them from installation site a...

Страница 18: ...5 24V 1 2 F FE N P N AB COM 1 2 3 4 5 6 7 8 9 DV 12 24V DV 12 24V COM NC 230v 17 EN CONNECTIONS MAP 09 CONNECTION SCHEME Flashing Light Barrier See diagram on page 19 Photocell Photocell CAPACITOR 10...

Страница 19: ...when the letters are inverted with the light sensor on the left L SENSE Only lights up when it detects that the brightness level is above the value regulated on the potentiometer INFORMATIVE LEDS LIGH...

Отзывы: