9A
9B
8A
8B
EN
EN
10
• P6 appears.
To program P6, continue in step 3 from P6 menu (page 8B).
To exit the programming press ↑↓ simultaneously.
05
• Appears the
function set from
factory. If you want,
change the it between
00 and 01 using ↑↓.
01
• Press MENU for 3
seconds.
00 (disables photocells)
01 (ables photocells)
With the photocells activated,
when someone interrupts them,
the barrier reverses the direction
set in HC.
00 (photocells during the closing)
01 (photocells during the opening)
This menu can only be changed
when the HE menu is active.
00 - photocell only intervenes
during closure and reverses in full
01 - photocell only intervenes in
opening and reverses for 2 sec.
(factory default
00
)
(factory default
00
)
02
• P0 appears.
Press ↓ five times.
03
• P5 appears.
Press MENU for 3
seconds.
PHOTOCELLS PROGRAMMING
04
• HE appears.
Press MENU for 3
seconds.
04. PROGRAMMING "P"
08
• Appears the
function set from
factory. If you want,
change the it between
00 and 01 using ↑↓.
06
• Press MENU for
3 seconds to confirm
the defined function.
07
• HC appears.
Press MENU for 3
seconds.
09
• Press MENU for
3 seconds to confirm
the defined function.
05
• Appears the
function set from
factory. If you
want, change the
it between 00 and
01 using ↑↓.
08
• Appears the
function set from
factory. If you
want, change the
it between 00 and
01 using ↑↓.
11
• Appears the
function set
from factory.
If you want,
change the it
between 00 and
01 using ↑↓.
12
• Press MENU for 3 seconds to
confirm the defined function.
P7 appears. To program P7, continue
in step 3 from P7 menu (page 9A).
To exit the programming press ↑↓
simultaneously.
02
• P0 appears.
Press ↓ six times.
03
• P6 appears.
Press MENU for 3
seconds.
04
• HE appears.
Press MENU for 3
seconds.
01
• Press MENU
for 3 seconds.
SAFETY BAND
00 (disables safety band)
01 (ables safety band)
The menu allows you to
enable/disable its operation.
00 (8k2 input)
01 (NC input)
You can only program HA if it
has HE enabled (page 9A).
Therefore, you can choose
safety band with 8k2 resistive
type (00) or safety band with
normally closed contact, NC
(01).
00 (band during closure)
01 (band during opening)
You can only program HA if
it has HE enabled (page 9A)
and after choose the type of
safety band in HA.
In closure (00) the barrier
reverses, in opening (01)
reverses only 2 seconds.
(factory default
00
)
(factory default
01
)
(factory default
00
)
10
•
HL appears.
Press MENU for 3
seconds.
07
• HA appears.
Press MENU for 3
seconds.
06
• Press MENU
for 3 seconds
to confirm the
defined function.
09
• Press MENU
for 3 seconds
to confirm the
defined function.
04. PROGRAMMING "P"