EN
17 ELECTRICAL CONNECTIONS
All electrical connections must be made with the unit disconnected from mains
power and, if applicable, battery power.
See the
CTRL
controller manual for instructions on making connections and
programming.
Before connecting to electrical power, ensure that the mains power specifications
on the identification plate match the mains power supply used.
A switch or an omnipolar cut-off switch with a contact opening of at least 3 mm
must be installed on the mains power line.
Ensure that an adequate residual current circuit breaker and a suitable overcurrent
cut-out are installed ahead of the electrical installation.
Use a 3x2.5 mm
2
double insulated cable for the mains power line.
Feed the cable on the left hand side of the barrier through the openings on the left
hand side of the controller casing and connect it to the terminals L (brown), N (blue)
and
(yellow/green) inside the automation unit.
Fasten the power cable with the cable grips included.
At least 50 mm of the connector cable conduit must protrude from the holes in the
base plate and into the automation unit.
Ensure that there are no sharp edges which could damage the power cable.
24
25
A
B
C
D
E
OFF
F
G
G
Z x4
BLACK
RED
BATTERY (+)
BATTERY C
SEC2
BATTERY (-)
1
2
3
4
5
ROSSO
RED
BLU/BLUE
NERO/BLACK (-)
(+)
18 INSTALLING THE BATTERY KIT (OPTIONAL)
1. Disconnect the mains power.
2. Unscrew the four screws [Z] and remove the head [A] (if applicable).
3. Lift the cable grommet [B] and disconnect the connector [C].
4. Open the transparent control unit cover [D].
5. Switch the control unit switch to the OFF position [E].
6. Lift the control unit and insert the batteries in their housing [F].
7. Connect the red, black and blue wires to the batteries (see detailed view)
8. Connect the batteries to the
+BATTERY
terminal (red wire) and
-BATTERY
terminal (black wire).
9. Insert the battery charge board
BI/BCHP
in the plug-in connector [G].
10. Reposition the control unit.
11. Switch the control unit switch to the ON position [E].
12. Reposition the transparent control unit cover [D].
13. Reconnect the connector [C] and close the cable grommet [B].
14. Close the head [A] and tighten the four front screws [Z].
15. Reconnect the mains power.
L
N