9. SUPPLEMENTARY FEATURES
Special supplementary software features can be
enabled on the 24-210/24-211 circuit boards The
features include: l
inear pot taper
,
0-20mA control
, e
mpty
bowl timer
,
low pulse rates,
and
two speed pots
. See
the S1 Switch Programming Chart. For more feature
information download (or request from RODIX) the FC-
40
Plus
Advanced Application Note 24-210/24-211.
10. STATUS LEDs
When any of the inputs are active, the associated LED
will turn ON. When the RUN input conditions are met,
the RUN LED will turn ON. See section 6 and the wiring
diagram’s ON/OFF Control Guide for more information
on how to satisfy the RUN conditions.
WARNING:
Fuses should be replaced with a Bussman ABC or
Littelfuse 3AB "Fast Acting" type or equivalent of
manufacturer's original value.
Mounting this control on a vibrating surface will
void the warranty.
WARRANTY
Rodix Control Products are Warranted to be free from
defects in material and workmanship under normal use
for a period of two years from date of shipment.
For the
full description of the warranty, terms, and software license,
please contact the factory.
For assistance installing or operating your Rodix Feeder
Cube® please call the factory or visit our web site. Technical
help is available to answer your questions and fax any needed
information. To return a control for IN or OUT of warranty
service, please ship it prepaid to:
Rodix Inc., ATTN: Repair Department
If under warranty, Rodix will repair or replace your control at
no charge; If out of warranty, we will repair it and you will be
billed for the repair charges (Time and Material) plus the
return freight. Quotes for repairs are available upon request.
A brief note describing the symptoms helps our technicians
address the issue.
Feeder Cube® is a registered TM of Rodix Inc.
DIMENSIONS
TROUBLESHOOTING
For the control to run: The
MAIN CONTROL DIAL
must be turned up or have over 4mA at the 4-
20mA input. Either the DIRECT LED must be lit or
both the INTERLOCK and EXT VOLTS LEDs must
be on. To light the DIRECT LED, connect a Run
Jumper at TB2-6 & TB2-7. To light the
INTERLOCK LED, a Run Jumper must connect
TB2-5 to TB2-6. To illuminate the EXT VOLTS
LED, TB2-11 & 12 needs a 10-30 VDC signal.
See the “FC-40 Plus Troubleshooting Guide” for
more information. If the feeder only hums, flip the
60/120 dip switch.
RODIX, INC.
2316 23
rd
Ave., Rockford, IL 61104
Toll Free (800) 562-1868, FAX (815) 316-4701
E-mail [email protected]
www.rodix.com
CE-48 Plus 24-211.doc 10/4/2012 Page 3
S1 Programming Chart
Program Description
S1 Switch Positions
SW3 SW4 SW5
Standard
Program
0 0 0
Linear Pot Taper
1
0
0
0-20mA
option
0 1 0
Empty Bowl Timer
1
1
0
Disable
LVC
0 0 1
2-Speed
Operation
1 0 1
30/40 Pulse Operation
0
1
1
Low Amplitude at “1”
1 1 1