10
SWITCH
5
11
5
FC-40 PLUS SERIES TERM STRIP TB-2
5
9
PADDLE
FC-40 PLUS SERIES TERM STRIP TB-2
12
J1
FEEDER BOWL/HOPPER INTERLOCK
8
12
OFF/ON CONTROL
5-30 VDC INPUT VOLTAGE
See section 6 of the Application Note for more
details.
7
7
-
B)
TERM STRIP TB-2, OUTPUT
+
8
6
OFF/ON CONTROL GUIDE
6
8
LOW CURRENT
SWITCH
7
9
LOW VOLTAGE INPUT SWITCHING
11
10
A)
C)
1
11
9
6
2
12
3
FC-40 PLUS SERIES TERM STRIP TB-2
FC-90 PLUS SERIES
10
(DC Voltage from PLC or FC-90 Plus)
9
4
7
10
7
3
12
6
1
9
5
10
LO A D
LINE VOLTAGE
G
TERM. STRIP
P/N 24-211
(SMALL)
A C HO T
FC-40 PLUS
+
Pot Input
AUX FEATURE
A C C O MMO N
TB2
120
TERM. STRIP
TB2
(TALL)
4 -2 0 mA
TB1
+
-
-
S1
TB1
RUN
Direct
Interlock
H1
So
ft
Mi
n
Ma
x
60 Rev
TRANSFORMER
1
Sig.
SIG
-
cw
+
100K
1/8W MIN
C O NTRO L
PO T
MA IN
Gr/Yl #20 AWG
TRIAC
(Plug as disconnect)
Bl #1
4
AW
G
Lt.
B
u #
14 A
W
G
Bl #1
4
AW
G
3
4
12
13
Spare
7
6
10
Gr/Yl #14 AWG
DOOR
SUB-PANEL
Bl #14 AWG
12
12
Bl #14 AWG
Lt. Bu #14 AWG
F1
12
Bl #1
4
AW
G
A1
Gate
Lt. Bu #14 AWG
OUTPUT
14
A2
3
3
Bl #1
4
AW
G
Lt.
B
u #
14 A
W
G
Vi #2
0
AW
G
3
4
4
Gr/Yl #14 AWG GND
8 A
9
7
INTERLOCK
TERMINALS
Bu #20 AWG
RUN JUMPER
RE
T
U
RN
IN
T
E
R
L
O
C
K
DI
RE
C
T
Bu #20 AWG
Bu #20 AWG
8
9
POWER SWITCH S1
Lt.
Bu
#
14
AWG
Bl #1
4 A
W
G
Lt.
Bu
#
14
AWG
Bl #
14
AWG
240 VAC
G
r/Y
l #14
AW
G
Bl
11
***4
50/60 Hz
Gn/Yl
COM
HOT
20VK1
1
2
LINE FILTER
Lt Bu
PE
Customer Supplied
Disconnect Device
PE
2
1
13
10
8
EU WIRING
11
INPUT
INTERLOCK
6
8
8
12
60
SW3
External
SW5
-
SW4
+
2
5
11
*** The common line is not fused in Europe. The common line should be fused for North American machine installations. Install the
HOT & COM fuses external to the control, or install fuse(s) for each unit by cutting the common wire that goes from the switch to the
terminal strip and add a fuse to it. Then apply wire number labels to the wire that connects to the switch.
Caution: Disconnect power before opening enclosure
Installation instructions:
When installing this control, a power supply disconnect device must be provided by the user. A power plug/socket combination can
be utilized for this purpose. The plug and socket must have a breaking capacity of at least the amperage of the vibratory feeder(s).
The size of the Mains supply wires should be 1.5mm² (#16 AWG) or larger.
The Mains supply wires should be fused by the Customer at 8 amps or less.
A1 GATE
TRIAC REFERENCE GUIDE
A2
RODIX INCORPORATED
2316 23
rd
Avenue, ROCKFORD IL 61104
TOLL FREE (800) 562-1868, FAX (815) 316-4701
E-mail [email protected]
www.rodix.com
CE-48 Plus W 24-211 4/27/2012
CE-48
PLUS
P/N 121-500-0750
4/27/12
2000, 2012 RODIX INC