Actuate the ON/OFF switch
2
.
•
Drill using an even forward feed. Do not
overload the machine.
•
The leaking water should be milky and not
clear.
•
Always loosen the locking screw
16
(Rodia 130/164) or the clamping lever
35
(Rodia 300) when drilling.
•
After drilling switch the machine off and
shut off the water tap.
dRILL stANd FIxAtIoN
CAUTION: The drill stand must
always be mounted firmly and must
not be able to move during drilling.
Secure using assembly
•
Drill the rawlplug hole Ø 15/16 mm (see
instruction rawlplug).
•
Insert rawlplug SD M12
•
Screw in assembly
25
.
•
Align the drill stand.
•
Fasten the drill stand with the spindle nut
24
.
Vacuum pump fixation
Setting up the vacuum pump
•
Position the machine horizontally. Maxi-
mum tilt of 10°.
•
Fasten, mount suction hose
42
and fasten
with hose clip
41
.
WARNING: Maximum drilling diam-
eter of 100 mm. Mount the drill
stand on an even, firm and smooth
surface using the vacuum pump,
never “over” head. Always con-
nect the core drill and the vacuum
pump to the same power outlet.
Never turn off the vacuum pump
during operation.
•
Install the vacuum kit.
•
Turn the fixation screws
21
ensuring, how-
ever, that the seal
29
is not squeezed.
•
Align the drill stand.
•
Mount the suction hose to the connection
for the vacuum pump
27
.
•
Close the ventilating tap
28
.
•
Connect quick coupling
43
to vacuum kit
27
on the drill stand.
•
The machine has no On/Off switch; it is
put into operation by inserting the mains
plug
45
into the socket.
•
The existing vacuum can be read from the
vacuum gauge
40
.
•
The vacuum gauge
40
must show a
vacuum of below -0.65 bar. If not check
for leakage.
•
Do not commence work until the required
vacuum has been reached.
•
Watch the vacuum gauge
40
while work-
ing. If the vacuum rises above -0.65 bar,
interrupt the work immediately and com-
pletely remove the drill stand.
Empty the fluid collecting container
•
If fluid is sucked in during operation, the
vacuum will no longer be maintained. Pull
the mains plug out immediately.
•
Unscrew the fluid collecting container
44
.
•
Remove the float and empty the container.
•
Replace the float and screw on the con-
tainer tightly again.
CAUTION: The machine becomes
hot after a long period of use. Do
not touch the machine directly after
operating it.
oveR heAd dRILLING
DANGER: When drilling “over”
head always secure the drill stand
with the assembly.