background image

 

User Manual – EC II GSM SE 

28 

8.4.11  Programmable alarm type 

EC II GSM SE has a number of pre-defined alarm types for different types of alarms. The fol-
lowing alarm types are used: 
 
 

Alarm type 

Decimal 

Hexadecimal 

 

 

Lift alarm 

10d  

0Ah 

 

Battery alarm 

17d  

11h 

 

Reset of battery 

12d  

0Ch 

 

Test alarm 

26d  

1Ah 

 

End-of-alarm 

28d 

1Ch 

 
If  using  one  of  the  available  alarm  button  inputs  to  generate  a  general  technical  alarm  from 
the lift the alarm type for that input must be changed from the default 10d. The alarm type to 
be used for a general technical alarm depends on the alarm receiver. Please check with the 
alarm central which alarm type to be used. See also section 5.2.1.10 above for more informa-
tion.  There  are  also  certain  types  of  automatically  alarm  receivers,  which  cannot  handle  in-
coming  lift  alarms  with  alarm  type  10d. With  the  following  programming  sequence  the  alarm 
type in the 

central unit

 can be changed: 

 

 

 

 

 

 

 <Alarm type> 

 

 
The  alarm  type  shall  always  be  entered  decimal  and  with  two  digits,  00-99.  Note  that  also 
ALBU 1 and ALBU 2 will use this alarm type.  
 
Reset to original alarm type 10d for the 

central unit

 with: 

 

 

 

 

 

 

  

 
To change the alarm type for the alarm button in the 

speech unit

 the following programming 

sequence is used: 
 

 

 

 

 

 

 <Alarm type> 

 

 
ALBU  1  and  ALBU  2  are  not  affected  by  this  programming  sequence.  The  alarm  type  shall 
always be entered decimal and with two digits, 00-99.  
 
Reset to original alarm type (10d) for the 

speech unit

 with: 

 

 

 

 

 

 

  

8.4.12  Change of security code 

To  be  able  to  remotely  program  EC  II  GSM  SE  you  must  know  the  security  code  of  EC  II 
GSM  SE.  At  delivery  the  code  is  pre-set  to  1111  but  can  be  altered  with  the  following  se-
quence: 
 

 

 

 

 

 

 <old code>

 

 

<new code>

 

 

<new code>

 

 

 
where 

<old code>

 and 

<new code>

 correspond to the old respective the new four-figured 

security code. 

8.4.13  Change of alarm flashing sequence 

When  any  of  the  alarm  buttons  has  been  activated  and  an  alarm  is  registered  by  the  lift 
phone, LED C in the Central Unit and the left LED in the Speech Unit become yellow. When 

Содержание EC II GSM SE

Страница 1: ...EC II GSM SE User Manual...

Страница 2: ...tionality 9 6 INSTALLATION 12 6 1 Installation of central unit 12 6 1 1 Installation of SIM card 14 6 1 2 Connection of battery 14 6 1 3 GSM antenna 14 6 1 4 Connection of speech unit 14 6 1 5 Alarm b...

Страница 3: ...ut 27 8 4 11 Programmable alarm type 28 8 4 12 Change of security code 28 8 4 13 Change of alarm flashing sequence 28 8 4 14 Stop sending battery alarm 29 8 4 15 Relay control 29 8 4 16 End of alarm 2...

Страница 4: ...red green yellow on the speech unit 45 14 FUSES IN CENTRAL UNIT 45 15 TROUBLESHOOTING 46 15 1 It is not possible to enter programming mode 46 15 2 F ltCom GSM SE does not make an alarm call 46 15 3 F...

Страница 5: ...duced adapted or transcribed after written permission from copyright proprietor Copyright 2011 3 1 Warranty There is a 2 year warranty 24 months for manufacturing failure or material failure commenc i...

Страница 6: ...freight charge The customer can ask for a quotation for repair of product not covered by warranty 4 General 4 1 Contents of packing Packing for EC II GSM SE contains following parts Central unit inclu...

Страница 7: ...uZink See above Emergency power Battery 12V 2Ah Powered by Central unit Power supply 230V 0 1A 50 60Hz Powered by Central unit Indications Three LED One is two colored Yellow and green LED and sound P...

Страница 8: ...6 Alarm button 2 ALBU 5 polig SPOX 2 50 mm Adapted for Part No 2122 7 Alarm button 3 ALBU 5 polig SPOX 2 50 mm Adapted for Part No 2122 8 Intercom 2 pol screw terminal block For standard telephone ac...

Страница 9: ...ces where there are an explosion hazard On places where chemical substances are used in a greater extent with particu lar regard to safety rules for environments filled with unstable gases or fumes 5...

Страница 10: ...wall or on ceiling of the lift car which eliminates the need to make holes other than those needed for the modular cable Intercon nection of the central unit and speech unit is very quick and simple s...

Страница 11: ...r for hearing impaired people The output is connected to voltage even after power failure on the condition that the emergency power supply has not been disconnected from the battery to protect it agai...

Страница 12: ...ust be able to receive the alarm type that is used for technical alarms 6 Installation Only competent and qualified personnel may install the EC II GSM SE Knowledge technical skill and correct equipme...

Страница 13: ...ed which is intended to be used by the EC II GSM SE It is also possible to mount the central unit in the machinery room if no good GSM signal is available on the lift car roof Then the modular cable b...

Страница 14: ...e EC II GSM SE Damages caused by incorrect battery types are not covered by warranty 6 1 3 GSM antenna The enclosed antenna is mounted in intended position in the chassis antenna contact on the extern...

Страница 15: ...put is protected with fuse as protection against possible short circuit see section 14 below 6 1 7 Intercom For communications between lift machine room and the lift car there is a possibility to conn...

Страница 16: ...M SE to the con trol equipment of the lift via the built in filter input By letting the lift decide if lift alarm should dial out the number of false alarms can be reduced For this function the contro...

Страница 17: ...be drilled next to those of the edges of the frame see the enclosed drill template Mounting of speech unit in the enclosed frame 6 2 3 Recessed mounting There is also a possibility to mount the speech...

Страница 18: ...al Unit One end of the enclosed modular cable is connected to socket in the central unit and the other end is connected to the speech unit input marked COM See picture above 7 Emergency power supply E...

Страница 19: ...button S1 on the printed circuit board of the central unit is used It will recharge the new battery completely and test it The battery can operate the equipment for at least 60 minutes as long as the...

Страница 20: ...tton S1 on the printed circuit board has been activated A battery reset command is sent via SMS If a battery is replaced after the EC II GSM SE has sent a battery alarm you should reset the battery al...

Страница 21: ...ou change the EC II GSM SE at for example a repair no new programming is needed apart from the PIN code as long as the same SIM card as before is used The keys on the keyboard of the speech unit have...

Страница 22: ...ically disconnected after 30 seconds if no key is pressed It is possible to manually exit the programming mode by pressing 8 3 Standard functions which must be programmed Below follows a description o...

Страница 23: ...o the central unit alarm button input Reset the alarm button in the central unit to breaking function NC with Program the following when an alarm button of closing type NO is connected to the speech u...

Страница 24: ...hes secondary receivers use the keypad on the back of the speech unit Check that the alarm reaches alarm receiver 2 by pressing programming mode EC II GSM SE immediately leaves the programming mode an...

Страница 25: ...m button You can change the time that the alarm button must be pressed down before an alarm is acti vated The default time is 5 seconds but this time may be changed between 1 and 30 sec onds Note that...

Страница 26: ...gits Enter alarm code for battery alarm with Alarm code max 10 digits Test the battery alarm receiver function in programming mode by enter After completed programming mode the EC II GSM SE immediatel...

Страница 27: ...IN code 8 4 10 Filter input To reduce the number of false alarms there is the possibility to connect EC II GSM SE to the control equipment of the lift via the built in filter input By letting the lift...

Страница 28: ...nit can be changed Alarm type The alarm type shall always be entered decimal and with two digits 00 99 Note that also ALBU 1 and ALBU 2 will use this alarm type Reset to original alarm type 10d for th...

Страница 29: ...tery is damaged or not mounted Even if the product is not allowed to call out battery alarm the LED will still indicate any eventual battery alarm 8 4 15 Relay control Default the relay in the central...

Страница 30: ...Note that it is only possible to use this functionality on speech units with front plates of stainless steel If the COP version is mounted behind a lift wall it is normally not possible to activate th...

Страница 31: ...ch unit not the green LED in the central unit Read more about the LED under section 13 below 8 4 19 Change of communication protocol Default the CPC protocol is used for communication between the lift...

Страница 32: ...above 9 2 Retrieving the telephone number To be able to program EC II GSM SE via SMS one must have access to the telephone num ber If that is not the case it is possible to find out by in programming...

Страница 33: ...y as separator before the parame ter value An SMS may not be longer than 160 characters If not all information fits in one sin gle SMS the programming may be split in several SMS Every SMS must start...

Страница 34: ...off E 0 alarm filter input off 1 alarm filter input active high 2 alarm filter input active low FF 00 99 alarm type for central unit alarm input ALBU1 ALBU2 G 0 traditional flash sequence for LED in...

Страница 35: ...655_09gg It has been up and running for 21 days 10 hours and 13 minutes The battery is on stand by charge and the current voltage is 12 123V Battery alarms are allowed to be called out and a battery...

Страница 36: ...pressing the switch S1 Note that this is exactly the same thing as pressing S1 on site The recharge cycle will be restarted which means that a forced charged of the battery is started follow by a res...

Страница 37: ...e when an alarm is trigged 3 Only an SMS is sent when an alarm is trigged For an SMS to be sent follow the three steps below 1 You must decide which types of alarm that will trigger an SMS 2 You must...

Страница 38: ...ne SMS from lift phone The alarm message can max be 80 letters long The letter A to E after SF3 in the SMS answer explains which type of alarms that have the SMS functionality activated See above for...

Страница 39: ...ot always accessible by default On some SIM cards this number must be entered manually Mount the SIM card in a standard mobile telephone enter the phone book and search for the correct settings If thi...

Страница 40: ...nd End of alarm since these alarm types can be set manually see section 8 4 11 and 8 4 16 above 9 9 Remote reset of the lift phone In some cases a complete reset of the lift phone is desired This is a...

Страница 41: ...larm button in speech unit alarm button in central unit ALBU 1 and ALBU 2 10 1 Alarms sent to a automatic alarm central It is recommended that all alarms from EC II GSM SE should be sent to a 24 7 man...

Страница 42: ...opportunity with alarm calls Note that all alarm receivers should practice the alarm handling procedure 10 2 1 Acknowledging an alarm Acknowledge the alarm with 4 ACKNOWLEDGE A voice communication ca...

Страница 43: ...to EC II GSM SE from a tone dialing phone or a mobile phone according to the following 1 Dial the number to the EC II GSM SE 2 EC II GSM SE answers after the first signal with a 4 tone 3 Press 4 to a...

Страница 44: ...tes function of GSM module Flashing sequence Information Green short flash Module connected to GSM net Green fixed light Network problem SIM card problem 13 1 3 LED C Three colored LED red green yello...

Страница 45: ...ress Green fixed light Speech connection intercom is in progress Red Green alternating Programming mode Red Green Red short flash Battery alarm Red alternating on off Network problem SIM card problem...

Страница 46: ...verage in the lift shaft Try to move central unit or mount it standing to improve the position of the antenna Another type of antenna might possibly be used In worst case the GSM covering so bad that...

Страница 47: ...Programming of phone number to primary alarm receiver Max 20 dig its 8 3 4 2 Phone No Programming of phone number to secondary alarm receiver Max 20 digits 8 3 4 3 Test of secondary alarm receiver 8 3...

Страница 48: ...arm function X 8 4 1 24 Code Alarm code to test alarm receiver Max 10 digits 8 4 1 25 Phone No Phone number to battery alarm re ceivers Max 20 digits 8 4 5 26 Test of battery alarm receiver 8 4 5 27 D...

Страница 49: ...de Unlocking of SIM card due to faulty entered PIN code Max 8 digits 8 4 9 44 Activation of filter input active high 8 4 10 45 Deactivation of filter input X 8 4 10 46 Activation of filter input activ...

Страница 50: ...8d 8 4 16 59 Activation of reed switch X 8 4 17 60 Deactivation of reed switch 8 4 17 61 Relay remotely controlled 8 4 15 62 Relay controlled by alarm button X 8 4 15 63 Old code New code New code Cha...

Отзывы: