PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
A-4
Supplemental Drive Information
IP20 (NEMA UL/Type Open)
Watts Loss
Watts loss data shown below is based on the rated current of the drive.
Important: For drives with 230V input, rated 150 HP / 521 A, the cooling
fans must be powered by an external 230V 50/60 Hz power
supply at terminals U3 & V3.
Fr
am
e
Drive Current Rating
Code
(1)
(1)
Catalog Number Explanation on page Preface-4
, positions 8-10 for corresponding drive HP rating,
armature amp rating and field amp rating.
Total Watts
Loss (W)
Fans
@ 230V
@ 460V
Voltage (V)
Rated Current (A) Air Capacity (m
3
/h)
A
7P0
4P1
131
–
–
–
9P0
6P0
012
010
020
014
–
019
029
027
186
–
–
–
038
035
254
Internal power supply
80
055
045
–
052
073
073
408
160
093
086
476
160
110
–
–
100
553
160
–
129
B
146
167
781
320
180
–
218
207
939
320
265
250
1038
320
–
330
1248
320
360
412
1693
680
434
–
C 521
495
2143
230
0.75
1050
–
667
2590
230
0.75
1050