In addition you can configure the following:
•
Par 763 [PID Feedback] contains the raw feedback counts from the
analog input signal received from the transducer position (dancer) or
tension (load cell)
•
Monitor the tension set point for a torque winder application in Par 1194
[Act Ten Ref Pct]
•
Configure the PID feedback gain in Par 1254 [PID Error Gain]
•
Limit the PID correction error using Par 757 [PID Clamp]
•
Monitor the actual error input to the PI and PD blocks in Par 759 [PID
Error]
Σ
+
+
P760
PID
S
etpoint 0
P761
PID
S
etpoint 1
P762
PID
S
etpoint
S
el
P76
3
PID Feed
ba
ck
P757
PID Cl
a
mp
P759
PID Error
P76
3
PID Feed
ba
ck
P1254
PID Error G
a
in
P1194
Act Ten Ref Pct